Network Working Group                                         J. Saperia
Request for Comments: 1289                 Digital Equipment Corporation
                                                           December 1991


                     
DECnet Phase IV MIB Extensions

Status of this Memo

This memo is an extension to the SNMP MIB. This RFC specifies an IAB standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "IAB Official Protocol Standards" for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Table of Contents

Abstract.......................................................... 1
1. Introduction................................................... 1
2. Selected Objects............................................... 2
3. Objects........................................................ 3
3.1 Format of Definitions......................................... 3
3.2 Textual Conventions........................................... 4
4. Object Definitions............................................. 4
5. Acknowledgements............................................... 63
6. References..................................................... 63
7. Security Considerations........................................ 64
8. Author's Address............................................... 64

Abstract

This memo defines a set of DECnet Phase IV extensions that have been created for the Internet MIB. When used in conjunction with the structure of management information (RFC 1155), the management information base for network management of TCP/IP-based internets (RFC 1213) and the Simple Network Management Protocol (RFC 1157), it will be possible to provide integrated network management of combined TCP/IP and DECnet Phase IV based internets. This document was produced by the DECnet Phase IV MIB working group of the Internet Engineering Task Force (IETF).
1.  Introduction

With the adoption of The Simple Network Management Protocol (RFC 1157), the management information base for network management of TCP/IP-based internets (RFC 1213), and the structure of management information (RFC 1155), by the Internet, and a large number of vendor implementations of these standards in commercially available products, it became possible to provide a higher level of effective network management in TCP/IP-based internets than previously available. With the growth in the use of these standards, network managers desired to use this environment as a base for providing integrated network management of multi-protocol networks.
DECnet Phase IV MIB Working Group                               [Page 1]


RFC 1289                  DECnet Phase IV MIB              December 1991

DECnet Phase IV is one widely used protocol which often coexists in IP-based internets. This memo provides the mechanisms by which IP- based management stations can effectively manage DECnet Phase IV based systems (especially router products) in an integrated fashion through the use of the standard Internet SMI, MIB and Simple Network Management Protocol.

DECnet Phase IV objects have been defined to be used in conjunction with the Internet MIB to allow access and control of these new objects by the Internet community. Additional support for other DECnet-based protocols such as RBMS (remote bridge management software) or other Digital Equipment Corporation Specific Hardware platforms is not included in this document.
2.  Selected Objects

The objects included in this memo have been created from the DIGITAL Network Architecture Network Management Functional Specification Version 4.0.0 Dated July 1983. An attempt has been made to provide a reasonable ordering of these variables into groups. These groups are:

o System Group

o Network Management Group

o Session Group

o End Group

o Routing Group

o Circuit Group

o DDCMP Group

o DDCMP Multipoint Control Group

o Ethernet Group

o Counters Group o Adjacency Group
DECnet Phase IV MIB Working Group                               [Page 2]


RFC 1289                  DECnet Phase IV MIB              December 1991

o Line Group

o Non Broadcast Line Group

o Area Group

An effort has also been made to preserve the original syntax of the object wherever possible, for example, a DECnet Phase IV object is Executor State. This was originally coded as a NICE (Network Information and Control Exchange) data type which is a Coded single field object of 1 byte in length. When converted for inclusion into the Internet MIB using the Internet SMI, it became an enumerated integer.
3.  Objects

All objects in this memo are described using the standard Internet SMI and BER of RFC 1155. A complete description of an object will include the name, syntax and encoding. Just as with objects supported in the MIB (RFC 1156), an object name is identified with an object identifier which has been administratively assigned. This identifies an Object Type. When an object type is combined with a specific instance, the particular object is uniquely identified. The use of Object Descriptors in this memo is consistent with that of RFC 1156 - they are text strings meant to be read by humans. The descriptors have been taken from the original DIGITAL Network Architecture Network Management Functional Specification Version 4.0.0 Dated July 1983 which defined DECnet Phase IV objects. These names were then massaged to put them in a form as consistent as possible with object type names listed in the standard Internet MIB. Object defintion information is also taken directly from the Network Architecture Network Managment Functional Specification cited above wherever possible. In this document, EXECUTOR is intended to reference only the DECnet software and is not intended to effect any other protocols which may be running on the system.
3.1  Format of Definitions

An object in this memo is specified by five fields of information: Object, Syntax, Definition, Access, and Status.

The OBJECT is a textual name (OBJECT DESCRIPTOR) for that object type combined with an administratively obtained OBJECT IDENTIFIER.

SYNTAX: For each object type, its abstract syntax is presented using the ASN.1 specified in RFC 1155. DEFINITION: A general description of the object type. Its original purpose in the DECnet Phase IV environment is given so that all implementers and users will consistently interpret the information contained in each object type. Changes in format to make the object consistent with RFC 1155 are also noted.
DECnet Phase IV MIB Working Group                               [Page 3]


RFC 1289                  DECnet Phase IV MIB              December 1991

ACCESS: The standard access keywords supported in RFC 1156 are used. The keywords used in this MIB are: read-only, read-write, and, not- accessible.

STATUS: The status field is used to describe with a single keyword whether the object type is mandatory or optional. Status keywords of obsolete and deprecated are not used in this memo since this is the first version of the DECnet Phase IV MIB.
3.2  Textual Conventions

New datatypes have been introduced as a textual conventions in this DECnet Phase IV MIB document. The purpose of these additions is to facilitate understanding of new objects in this MIB. No changes to the SMI or the SNMP are necessary to support these conventions which are described in 4.0 (Object Definitions).
4.  Object Definitions

RFC1289-phivMIB

DEFINITIONS ::= BEGIN

IMPORTS
Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
mib-2, DisplayString
FROM RFC1213-MIB;

-- DECNet Phase-IV MIB

phiv OBJECT IDENTIFIER ::= { mib-2 18 }

-- textual conventions

PhivAddr ::= OCTET STRING (SIZE (2)) -- This data type is intended as a short word representation of -- standard DECnet Phase IV addresses. DECnet addresses are -- hierarchically structured numbers assigned to a particular -- DECnet node. The address is structured so that the area -- number is contained in the most significant 6 bits of the -- first octet. The next 2 bits of the first octet contain -- the first two bits of the host address. The remainder of -- the host address is contained in the second octet.
DECnet Phase IV MIB Working Group                               [Page 4]


RFC 1289                  DECnet Phase IV MIB              December 1991

PhivCounter ::= INTEGER -- This data type has been created for DECnet counters. These -- counters latch at their maximum specified value until either -- the system is restared, or they are reset to zero by the user -- or management software.

-- groups in the decnetiv mib

phivSystem OBJECT IDENTIFIER ::= { phiv 1 } phivManagement OBJECT IDENTIFIER ::= { phiv 2 } session OBJECT IDENTIFIER ::= { phiv 3 } end OBJECT IDENTIFIER ::= { phiv 4 } routing OBJECT IDENTIFIER ::= { phiv 5 } circuit OBJECT IDENTIFIER ::= { phiv 6 } ddcmp OBJECT IDENTIFIER ::= { phiv 7 } control OBJECT IDENTIFIER ::= { phiv 8 } ethernet OBJECT IDENTIFIER ::= { phiv 9 } counters OBJECT IDENTIFIER ::= { phiv 10 } adjacency OBJECT IDENTIFIER ::= { phiv 11 } line OBJECT IDENTIFIER ::= { phiv 12 } nonBroadcastLine OBJECT IDENTIFIER ::= { phiv 14 } area OBJECT IDENTIFIER ::= { phiv 15 }

-- System Group

-- The implementation of the System Group is mandatory for -- all systems.

phivSystemState OBJECT-TYPE
SYNTAX INTEGER {
on (1), off (2), shut (3), restricted (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This represents the operational state of the executor node.
                The possible states are:
                ON          Allows logical links.
                OFF         Allows no new links, terminates existing



DECnet Phase IV MIB Working Group                               [Page 5]


RFC 1289                  DECnet Phase IV MIB              December 1991


links, and stops routing traffic through.
SHUT Allows no new logical links, does not
destroy existing logical links, and goes to the OFF state when all logical links are gone.
RESTRICTED Allows no new incoming logical links from
other nodes.

NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155)."
::= { phivSystem 1 }

phivExecIdent OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) ) ACCESS read-write STATUS mandatory DESCRIPTION "This is a text string that describes the executor node (for example, 'Research Lab'). The string is up to 32 characters of any type."
::= { phivSystem 2 }

-- Network Management Group

-- The implementation of the Network Management Group is -- mandatory for all systems which contain a DECnet style -- management version.


phivMgmtMgmtVers OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255) ) ACCESS read-only STATUS mandatory DESCRIPTION "This is the read-only Network Management Version, consisting of the version number, the Engineering Change Order (ECO) number, and the user ECO number (for example, 3.0.0). This parameter applies to the executor node only."
::= { phivManagement 1 }

-- Session Layer Group

-- The implementation of the Session Layer Group is mandatory for -- all systems that implement session layer communications. phivSessionSystemName OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..6) ) ACCESS read-only STATUS mandatory DESCRIPTION "Name to be associated with the node identification. Only one name can be assigned to a node address or a circuit identification. No name should be used more than once in a DECnet network. Node-name is one to six upper case alphanumeric characters with at least one alpha character. A length of 0 indicates no name."




DECnet Phase IV MIB Working Group                               [Page 6]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { session 1 }

phivSessionInTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum duration between the time a connect is received for a process at the executor node and the time that process accepts or rejects it. If the connect is not accepted or rejected by the user within the number of seconds specified, Session Control rejects it for the user. A 0 indicates no timer is running."
::= { session 2 }

phivSessionOutTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the duration between the time the executor requests a connect and the time that connect is acknowledged by the destination node. If the connect is not acknowledged within the number of seconds specified, Session Control returns an error. A 0 indicates no timer is running."
::= { session 3 }

-- End Communication Layer Group

-- The implementation of the End Communication Layer Group is -- mandatory for all systems that implement end layer -- communications.

-- Remote State Table phivEndRemoteTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivEndRemoteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the state of sessions between the node under study and the nodes found in the table."



DECnet Phase IV MIB Working Group                               [Page 7]


RFC 1289                  DECnet Phase IV MIB              December 1991



::= { end 1 }

phivEndRemoteEntry OBJECT-TYPE
SYNTAX PhivEndRemoteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a particular remote node as seen from the end communication layer." INDEX { phivEndRemoteHostNodeID } ::= { phivEndRemoteTable 1 }

PhivEndRemoteEntry ::=
SEQUENCE {
phivEndRemoteHostNodeID
PhivAddr,
phivEndRemoteState
INTEGER,
phivEndCircuitIndex
INTEGER,
phivEndActiveLinks
INTEGER,
phivEndDelay
INTEGER (0..65535)
}
phivEndRemoteHostNodeID OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This value is the address of the remote node to be evaluated."
::= { phivEndRemoteEntry 1 }

phivEndRemoteState OBJECT-TYPE
SYNTAX INTEGER {
on (1), off (2), shut (3), restricted (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This represents the operational state of the remote node being evaluated. The possible states are:


DECnet Phase IV MIB Working Group                               [Page 8]


RFC 1289                  DECnet Phase IV MIB              December 1991



               ON          Allows logical links.
               OFF         Allows no new links, terminates existing
links, and stops routing traffic through.
SHUT Allows no new logical links, does not
destroy existing logical links, and goes to the OFF state when all logical links are gone.
RESTRICTED Allows no new incoming logical links from
other nodes.

NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155."
::= { phivEndRemoteEntry 2 }

phivEndCircuitIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index value for each known circuit used to communicate with the remote node. This is the same value as phivCircuitIndex."
::= { phivEndRemoteEntry 3 }

phivEndActiveLinks OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter represents the number of active logical links from the executor to the destination node."
::= { phivEndRemoteEntry 4 }

phivEndDelay OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter is the average round trip delay in seconds to the destination node. This parameter is kept on a remote node basis."


DECnet Phase IV MIB Working Group                               [Page 9]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivEndRemoteEntry 5 }

-- End System Counter Table

phivEndCountTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivEndCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the counters associated with each end system that is known to the entity. These counters reflect totals from the perspective of the executor node."
::= { end 2 }

phivEndCountEntry OBJECT-TYPE
SYNTAX PhivEndCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a particular session between two end systems." INDEX { phivEndCountHostNodeID } ::= { phivEndCountTable 1 }

PhivEndCountEntry ::=
SEQUENCE {
phivEndCountHostNodeID
PhivAddr,
phivEndCountSecsLastZeroed
PhivCounter (0..65535),
phivEndCountUsrBytesRec
PhivCounter,
phivEndCountUsrBytesSent
PhivCounter,
phivEndUCountUsrMessRec
PhivCounter,
phivEndCountUsrMessSent
PhivCounter,
phivEndCountTotalBytesRec
PhivCounter,
phivEndCountTotalBytesSent
PhivCounter,
phivEndCountTotalMessRec
PhivCounter,
phivEndCountTotalMessSent


DECnet Phase IV MIB Working Group                              [Page 10]


RFC 1289                  DECnet Phase IV MIB              December 1991


PhivCounter,
phivEndCountConnectsRecd
PhivCounter (0..65535),
phivEndCountConnectsSent
PhivCounter (0..65535),
phivEndCountReponseTimeouts
PhivCounter (0..65535),
phivEndCountRecdConnectResErrs
PhivCounter (0..65535)
}
phivEndCountHostNodeID OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This value is the address of the remote node to be evaluated."
::= { phivEndCountEntry 1 }

phivEndCountSecsLastZeroed OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value is the number of seconds that have elapsed since the counters for the node in this table row were last set to zero. This counter is located in the network management layer, but is returned with the end system information which follows."
::= { phivEndCountEntry 2 }

phivEndCountUsrBytesRec OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of user bytes received from the target host."
::= { phivEndCountEntry 3 }

phivEndCountUsrBytesSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of user bytes sent to the target host."
::= { phivEndCountEntry 4 }




DECnet Phase IV MIB Working Group                              [Page 11]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivEndUCountUsrMessRec OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of user messages received from the target host."
::= { phivEndCountEntry 5 }

phivEndCountUsrMessSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of user messages sent to the target host."
::= { phivEndCountEntry 6 }

phivEndCountTotalBytesRec OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of bytes received from the target host."
::= { phivEndCountEntry 7 }

phivEndCountTotalBytesSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of bytes sent to the target host."
::= { phivEndCountEntry 8 }

phivEndCountTotalMessRec OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of messages received from the target host."
::= { phivEndCountEntry 9 }

phivEndCountTotalMessSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of messages sent to the target host."
::= { phivEndCountEntry 10 }



DECnet Phase IV MIB Working Group                              [Page 12]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivEndCountConnectsRecd OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of connects received from the target host."
::= { phivEndCountEntry 11 }

phivEndCountConnectsSent OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of connects sent to the target host."
::= {phivEndCountEntry 12 }

phivEndCountReponseTimeouts OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of response timeouts."
::= { phivEndCountEntry 13 }

phivEndCountRecdConnectResErrs OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of received connect resource errors."
::= {phivEndCountEntry 14 }


-- additional End System objects

phivEndMaxLinks OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum active logical link count allowed for the executor."
::= { end 3 }

phivEndNSPVers OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) ) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter represents the version number of the node End Communication S/W. The format is version number, ECO, and user ECO, e.g., 4.1.0"


DECnet Phase IV MIB Working Group                              [Page 13]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { end 4 }

phivEndRetransmitFactor OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of times the source End Communication at the executor node will restart the retransmission timer when it expires. If the number is exceeded, Session Control disconnects the logical link for the user."
::= { end 5 }

phivEndDelayFact OBJECT-TYPE
SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the number by which to multiply one sixteenth of the estimated round trip delay to a node to set the retransmission timer to that node."
::= { end 6 }

phivEndDelayWeight OBJECT-TYPE
SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This number represents the weight to apply to a current round trip delay estimate to a remote node when updating the estimated round trip delay to a node. On some systems the number must be 1 less than a power of 2 for computational efficiency."
::= { end 7 }

phivEndInactivityTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum duration of inactivity (no data in either direction) on a logical link before the node checks to see if the logical link still works. If no activity occurs within the minimum number of seconds, End Communication generates artificial traffic to test the link (End Communication specification)."


DECnet Phase IV MIB Working Group                              [Page 14]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { end 8 }

phivEndCountZeroCount OBJECT-TYPE
SYNTAX INTEGER {
other (1), reset (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this value is set to 2, all of the counters in the End System Counter Table are set to zero."
::= { end 9 }

phivEndMaxLinksActive OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the high water mark for the number of links that were active at any one time."
::= { end 10 }

-- Routing Layer Group

-- The implementation of the Routing Layer Group is mandatory for -- all systems that implement level 1 routing layer -- communications.

phivRouteBroadcastRouteTimer OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION
"This value determines the maximum time in seconds
allowed between Routing updates on Ethernet circuits. When this timer expired before a routing update occurs, a routing update is forced. With a standard calculation, Routing also uses this timer to enforce a minimum delay between routing updates."
::= { routing 1 }

phivRouteBuffSize OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION


DECnet Phase IV MIB Working Group                              [Page 15]


RFC 1289                  DECnet Phase IV MIB              December 1991


"This parameter value determines the maximum size of
a Routing message. It therefore determines the maximum size message that can be forwarded. This size includes protocol overhead down to and including the End Communication layer, plus a constant value of 6. (This value of 6 is included to provide compatibility with the parameter definition in Phase III, which included the Routing overhead.) It does not include Routing or Data link overhead (except for the constant value of 6). There is one buffer size for all circuits.

NOTE: The BUFFER SIZE defines the maximum size messages that the Routing layer can forward. The SEGMENT BUFFER SIZE (defined below) defines the maximum size messages that the End Communication layer can transmit or receive. The SEGMENT BUFFER SIZE is always less than or equal to the BUFFER SIZE. Normally the two parameters will be equal. They may be different to allow the network manager to alter buffer sizes on all nodes without interruption of service. They both include an extra 6 bytes for compatibility with Phase III."
::= { routing 2 }

phivRouteRoutingVers OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..255) ) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter identifies the executor node's Routing version number. The format is version number, ECO, and user ECO, e.g., 4.1.0"
::= { routing 3 }

phivRouteMaxAddr OBJECT-TYPE
SYNTAX INTEGER (1..1023) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the largest node number and, therefore, number of nodes that can be known about by the executor node's home area."
::= { routing 4 }




DECnet Phase IV MIB Working Group                              [Page 16]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivRouteMaxBdcastNonRouters OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum total number of nonrouters the executor node can have on its Ethernet circuits."
::= { routing 5 }

phivRouteMaxBdcastRouters OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum total number of routers the executor node can have on its Ethernet circuits."
::= { routing 6 }

phivRouteMaxBuffs OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of transmit buffers that Routing may use for all circuits."
::= { routing 7 }

phivRouteMaxCircuits OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of Routing circuits that the executor node can know about."
::= { routing 8 }

phivRouteMaxCost OBJECT-TYPE
SYNTAX INTEGER (1..1022) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum total path cost allowed from the executor to any node within an area. The path cost is the sum of the circuit costs along a path between two nodes. This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the cost of the least costly path to the other node is excessive. For correct operation, this parameter must not be less than the maximum path cost of the network."


DECnet Phase IV MIB Working Group                              [Page 17]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { routing 9 }

phivRouteMaxHops OBJECT-TYPE
SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of routing hops allowable from the executor to any other reachable node within an area. (A hop is the logical distance over a circuit between two adjacent nodes.) This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the length of the shortest path between the two nodes is too long. For correct operation, this parameter must not be less than the network diameter. (The network diameter is the reachability distance between the two nodes of the network having the greatest reachability distance, where reachability distance is the length the shortest path between a given pair of nodes.)"
::= { routing 10 }

phivRouteMaxVisits OBJECT-TYPE
SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of nodes a message coming into the executor node can have visited. If the message is not for this node and the MAXIMUM VISITS number is exceeded, the message is discarded. The MAXIMUM VISITS parameter defines the point where the packet lifetime control algorithm discards a packet that has traversed too many nodes. For correct operation, this parameter must not be less than the maximum path length of the network. (The maximum path length is the routing distance between the two nodes of the network having the greatest routing distance, where routing distance is the length of the least costly path between a given pair of nodes.)"
::= { routing 11 }



DECnet Phase IV MIB Working Group                              [Page 18]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivRouteRoutingTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value determines the maximum time in seconds allowed between Routing updates on non-Ethernet circuits. When this timer expires before a routing update occurs, a routing update is forced."
::= { routing 12 }

phivRouteSegBuffSize OBJECT-TYPE
SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter value determines the maximum size of an end-to-end segment. The size is a decimal integer in the range 1-65535. This size is in bytes. This size includes protocol overhead down to and including the End Communication layer, plus a constant value of 6. (This value of 6 is included to provide compatibility with the BUFFER SIZE parameter definition.) It does not include Routing or Data link overhead (except for the constant value of 6)."
::= { routing 13 }

phivRouteType OBJECT-TYPE
SYNTAXINTEGER {
routing-III (1), nonrouting-III (2), area (3), routing-IV (4), nonrouting-IV (5) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the type of the executor node. The node-type is one of the following:

routing-III nonrouting-III routing-IV ronrouting-IV area

A routing node has full routing capability. A nonrouting node contains a subset of the Routing routing modules. The III and IV indicate the DNA phase of the node. Nonrouting nodes can deliver and receive packets to and from any node, but cannot route packets from other nodes through to other nodes. An area node routes between areas. Refer to the Routing specification for details.


DECnet Phase IV MIB Working Group                              [Page 19]


RFC 1289                  DECnet Phase IV MIB              December 1991



For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The ROUTING-III and NONROUTING-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155)"
::= { routing 14 }

phivRouteCountAgedPktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of aged packet losses."
::= { routing 15 }

phivRouteCountNodeUnrPktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of node unreachable packet losses."
::= { routing 16 }

phivRouteCountOutRngePktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of node out-of-range packet losses."
::= { routing 17 }

phivRouteCountOverSzePktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of Oversized packet losses."
::= { routing 18 }




DECnet Phase IV MIB Working Group                              [Page 20]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivRouteCountPacketFmtErr OBJECT-TYPE
SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of packet format errors."
::= { routing 19 }

phivRouteCountPtlRteUpdtLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of partial routing update losses."
::= { routing 20 }

phivRouteCountVerifReject OBJECT-TYPE
SYNTAX PhivCounter (0..127) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of verification rejects."
::= { routing 21 }

-- Level 1 Routing Table

phivLevel1RouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivLevel1RouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the currently known DECnet Phase IV Routes."
::= { routing 22 }

phivLevel1RouteEntry OBJECT-TYPE
SYNTAX PhivLevel1RouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the currently known DECnet Phase IV Routes." INDEX { phivLevel1RouteNodeAddr } ::= { phivLevel1RouteTable 1 }

PhivLevel1RouteEntry ::=
SEQUENCE {
phivLevel1RouteNodeAddr


DECnet Phase IV MIB Working Group                              [Page 21]


RFC 1289                  DECnet Phase IV MIB              December 1991


PhivAddr,
phivLevel1RouteCircuitIndex
INTEGER,
phivLevel1RouteCost
INTEGER (0..65535),
phivLevel1RouteHops
INTEGER (0..127),
phivLevel1RouteNextNode
PhivAddr
}
phivLevel1RouteNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This value is the address of the node about which routing information is contained in this level 1 routing table."
::= { phivLevel1RouteEntry 1 }

phivLevel1RouteCircuitIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index value for each known circuit. This is the index to the circuit state table and is the same value as phivCircuitIndex."
::= { phivLevel1RouteEntry 2 }

phivLevel1RouteCost OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter represents the total cost over the current path to the destination node. Cost is a positive integer value associated with using a circuit. Routing routes messages (data) along the path between two nodes with the smallest cost. COST is kept on a remote node basis."
::= { phivLevel1RouteEntry 3 }

phivLevel1RouteHops OBJECT-TYPE
SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter represents the number of hops over to a destination node. A hop is Routing value representing the logical distance between two nodes in a network. HOPS is kept on a remote node basis."


DECnet Phase IV MIB Working Group                              [Page 22]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivLevel1RouteEntry 4 }

phivLevel1RouteNextNode OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only value indicates the next node on the circuit used to get to the node under scrutiny (next hop)."
::= { phivLevel1RouteEntry 5 }

-- Additional routing parameters

phivRouteCountZeroCount OBJECT-TYPE
SYNTAX INTEGER {
other (1), reset (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this value is set to 2, the following objects are set to Zero: phivRouteCountAgedPktLoss, phivRouteCountNodeUnrPktLoss, phivRouteCountOutRngePktLoss, phivRouteCountOverSzePktLoss, phivRouteCountPacketFmtErr, phivRouteCountPtlRteUpdtLoss, and phivRouteCountVerifReject."
::= { routing 23 }

phivRouteSystemAddr OBJECT-TYPE
SYNTAX PhivAddr ACCESS read-only STATUS mandatory DESCRIPTION
"DECnet Phase IV node address."
::= { routing 24 }
DECnet Phase IV MIB Working Group                              [Page 23]


RFC 1289                  DECnet Phase IV MIB              December 1991
-- Circuit Group

-- The implementation of the Circuit Group is mandatory for -- all systems.

-- Circuit Parameters Table


phivCircuitParametersTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivCircuitParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the parameters associated with all circuits currently known."
::= {circuit 1 }

phivCircuitParametersEntry OBJECT-TYPE
SYNTAX PhivCircuitParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameters information about all circuits currently known." INDEX { phivCircuitIndex } ::= { phivCircuitParametersTable 1 }

PhivCircuitParametersEntry ::=
SEQUENCE {
phivCircuitIndex
INTEGER,
phivCircuitLineIndex
INTEGER,
phivCircuitCommonState
INTEGER,
phivCircuitCommonSubState
INTEGER,
phivCircuitCommonName
DisplayString,
phivCircuitExecRecallTimer
INTEGER (0..65535),
phivCircuitCommonType
INTEGER,
phivCircuitService
INTEGER,
phivCircuitExecCost
INTEGER (1..25),
phivCircuitExecHelloTimer


DECnet Phase IV MIB Working Group                              [Page 24]


RFC 1289                  DECnet Phase IV MIB              December 1991


INTEGER (1..8191)
}
phivCircuitIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION
"A unique index value for each known circuit."
::= { phivCircuitParametersEntry 1 }

phivCircuitLineIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The line on which this circuit is active. This is the same as the IfIndex."
::= { phivCircuitParametersEntry 2 }

phivCircuitCommonState OBJECT-TYPE
SYNTAX INTEGER {
on (1), off (2), service (3), cleared (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the circuit's Network Management operational state. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155."
::= { phivCircuitParametersEntry 3 }

phivCircuitCommonSubState OBJECT-TYPE
SYNTAX INTEGER {
starting (1), reflecting (2), looping (3), loading (4), dumping (5), triggering (6), autoservice (7), autoloading (8), autodumping (9), autotriggering (10), synchronizing (11), failed (12), running (13) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the circuit's Network Management operational and service substate. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155."


DECnet Phase IV MIB Working Group                              [Page 25]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivCircuitParametersEntry 4 }

phivCircuitCommonName OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..16) ) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the circuit entry in the table, for example, SVA-0 or in a level 2 router ASYNC-8 or ETHER-1)."
::= { phivCircuitParametersEntry 5 }

phivCircuitExecRecallTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter represents the minimum number of seconds to wait before restarting the circuit. A value of 0 indicates not timer is running."
::= { phivCircuitParametersEntry 6 }

phivCircuitCommonType OBJECT-TYPE
SYNTAX INTEGER {
ddcmp-point (1), ddcmp-control (2), ddcmp-tributary (3), x25 (4), ddcmp-dmc (5), ethernet (6), ci (7), qp2-dte20 (8), bisync (9), other (14), fddi (15) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the type of the circuit. For X.25 circuits, the value must be set to X25. For DDCMP and Ethernet circuits it is read only and is the same value as the protocol of the associated line. NOTE: Values 1 - 5 are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155."


DECnet Phase IV MIB Working Group                              [Page 26]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivCircuitParametersEntry 7 }

phivCircuitService OBJECT-TYPE
SYNTAX INTEGER {
enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This value indicates whether or not Network Management allows service operations on a circuit. The values for service-control are as follows:

ENABLED SERVICE state and/or service functions are
allowed.

DISABLED SERVICE state and/or service functions are not
allowed.

NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155."
::= { phivCircuitParametersEntry 8 }

phivCircuitExecCost OBJECT-TYPE
SYNTAX INTEGER (1..25) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the routing cost of the circuit. Routing sends messages along the path between two nodes having the smallest cost."
::= { phivCircuitParametersEntry 9 }

phivCircuitExecHelloTimer OBJECT-TYPE
SYNTAX INTEGER (1..8191) ACCESS read-write STATUS mandatory DESCRIPTION "This value determines the frequency of Routing Hello messages sent to the adjacent node on the circuit."


DECnet Phase IV MIB Working Group                              [Page 27]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivCircuitParametersEntry 10 }

-- Circuit Counters Table


phivCircuitCountTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivCircuitCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the counters associated with all circuits currently known."
::= { circuit 2 }

phivCircuitCountEntry OBJECT-TYPE
SYNTAX PhivCircuitCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"Counter information about all circuits currently known"
INDEX { phivCircuitIndex } ::= { phivCircuitCountTable 1 }

PhivCircuitCountEntry ::=
SEQUENCE {
phivCircuitCountSecLastZeroed
PhivCounter (0..65535),
phivCircuitCountTermPacketsRecd
PhivCounter,
phivCircuitCountOriginPackSent
PhivCounter,
phivCircuitCountTermCongLoss
PhivCounter (0..65535),
phivCircuitCountCorruptLoss
PhivCounter (0..255),
phivCircuitCountTransitPksRecd
PhivCounter,
phivCircuitCountTransitPkSent
PhivCounter,
phivCircuitCountTransitCongestLoss
PhivCounter (0..65535),
phivCircuitCountCircuitDown
PhivCounter (0..255),
phivCircuitCountInitFailure
PhivCounter (0..255),
phivCircuitCountAdjDown
PhivCounter,


DECnet Phase IV MIB Working Group                              [Page 28]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivCircuitCountPeakAdj
PhivCounter,
phivCircuitCountBytesRecd
PhivCounter,
phivCircuitCountBytesSent
PhivCounter,
phivCircuitCountDataBlocksRecd
PhivCounter (0..65535),
phivCircuitCountDataBlocksSent
PhivCounter,
phivCircuitCountUsrBuffUnav
PhivCounter (0..65535)
}
phivCircuitCountSecLastZeroed OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds since the circuit counters for this circuit were last zeroed."
::= { phivCircuitCountEntry 1 }

phivCircuitCountTermPacketsRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of terminating packets received on this circuit."
::= { phivCircuitCountEntry 2 }

phivCircuitCountOriginPackSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of originating packets sent on this circuit."
::= { phivCircuitCountEntry 3 }

phivCircuitCountTermCongLoss OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of terminating congestion losses on this circuit."
::= { phivCircuitCountEntry 4 }




DECnet Phase IV MIB Working Group                              [Page 29]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivCircuitCountCorruptLoss OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of corruption losses on this circuit."
::= { phivCircuitCountEntry 5 }

phivCircuitCountTransitPksRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of Transit packets received on this circuit."
::= { phivCircuitCountEntry 6 }

phivCircuitCountTransitPkSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of transit packets sent on this circuit."
::= { phivCircuitCountEntry 7 }

phivCircuitCountTransitCongestLoss OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of transit congestion losses on this circuit."
::= { phivCircuitCountEntry 8 }

phivCircuitCountCircuitDown OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of circuit downs on this circuit."
::= { phivCircuitCountEntry 9 }

phivCircuitCountInitFailure OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of Initialization failures on this circuit."
::= { phivCircuitCountEntry 10 }



DECnet Phase IV MIB Working Group                              [Page 30]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivCircuitCountAdjDown OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "This counter indicates the number of adjacency losses that result from any of the following: Node listener timeout Invalid data received at node listener Unexpected control (initialization or verification)
message received
Routing message received with a checksum error Node identification from a routing message or a Hello message that is not the one expected Hello message received indicating that connectivity became one-way Adjacency idled."
::= { phivCircuitCountEntry 11 }

phivCircuitCountPeakAdj OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "This counter indicates the maximum number of nodes that are up on the circuit."
::= { phivCircuitCountEntry 12 }

phivCircuitCountBytesRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of bytes received on this circuit."
::= { phivCircuitCountEntry 13 }

phivCircuitCountBytesSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of bytes sent on this circuit."
::= { phivCircuitCountEntry 14 }

phivCircuitCountDataBlocksRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION


DECnet Phase IV MIB Working Group                              [Page 31]


RFC 1289                  DECnet Phase IV MIB              December 1991


"Number of data blocks received on this circuit."
::= { phivCircuitCountEntry 15 }

phivCircuitCountDataBlocksSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of data blocks sent on this circuit."
::= { phivCircuitCountEntry 16 }

phivCircuitCountUsrBuffUnav OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of user buffer unavailable errors."
::= { phivCircuitCountEntry 17 }

-- Additional Circuit Parameters

phivCircuitOrigQueueLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter indicates the maximum number of originating packets that may be outstanding on this circuit. This does not include route-thru traffic."
::= { circuit 3 }

phivCircuitCountZeroCount OBJECT-TYPE
SYNTAX INTEGER {
other (1), reset (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this value is set to 2, all of the counters in the Circuit Counter Table are set to zero."
::= { circuit 4 }

-- DDCMP Circuit Group

-- The implementation of the DDCMP Circuit Group is mandatory for -- all systems which support DDCMP circuits. -- DDCMP Parameters Table


DECnet Phase IV MIB Working Group                              [Page 32]


RFC 1289                  DECnet Phase IV MIB              December 1991




phivDDCMPCircuitParametersTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivDDCMPCircuitParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"Information about DDCMP circuit parameters."
::= { ddcmp 1}

phivDDCMPCircuitParametersEntry OBJECT-TYPE
SYNTAX PhivDDCMPCircuitParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"Parameters information about DDCMP circuits currently
known."
INDEX { phivDDCMPCircuitIndex } ::= { phivDDCMPCircuitParametersTable 1 }

PhivDDCMPCircuitParametersEntry ::=
SEQUENCE {
phivDDCMPCircuitIndex
INTEGER,
phivDDCMPCircuitAdjNodeAddr
INTEGER (0..65535),
phivDDCMPCircuitTributary
INTEGER (0..255)
}
phivDDCMPCircuitIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index value for each known DDCMP circuit. This is the same value as phivCircuitIndex."
::= { phivDDCMPCircuitParametersEntry 1 }

phivDDCMPCircuitAdjNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION
"The address of the adjacent node."
::= { phivDDCMPCircuitParametersEntry 2 }




DECnet Phase IV MIB Working Group                              [Page 33]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivDDCMPCircuitTributary OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the Data Link physical tributary address of the circuit."
::= { phivDDCMPCircuitParametersEntry 3 }

-- DDCMP Circuit Counter Table

phivDDCMPCircuitCountTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivDDCMPCircuitCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the DDCMP counters associated with all circuits currently known."
::= { ddcmp 2 }

phivDDCMPCircuitCountEntry OBJECT-TYPE
SYNTAX PhivDDCMPCircuitCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"Counter information about DDCMP circuits now known"
INDEX { phivCircuitIndex } ::= { phivDDCMPCircuitCountTable 1 }

PhivDDCMPCircuitCountEntry ::=
SEQUENCE {
phivDDCMPCircuitErrorsInbd
PhivCounter (0..255),
phivDDCMPCircuitErrorsOutbd
PhivCounter (0..255),
phivDDCMPCircuitRmteReplyTimeouts
PhivCounter (0..255),
phivDDCMPCircuitLocalReplyTimeouts
PhivCounter (0..255),
phivDDCMPCircuitRmteBuffErrors
PhivCounter (0..255),
phivDDCMPCircuitLocalBuffErrors
PhivCounter (0..255),
phivDDCMPCircuitSelectIntervalsElap
PhivCounter (0..65535),
phivDDCMPCircuitSelectTimeouts
PhivCounter (0..255)
}


DECnet Phase IV MIB Working Group                              [Page 34]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivDDCMPCircuitErrorsInbd OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of Data errors inbound."
::= { phivDDCMPCircuitCountEntry 1 }

phivDDCMPCircuitErrorsOutbd OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of outbound data errors."
::= { phivDDCMPCircuitCountEntry 2 }

phivDDCMPCircuitRmteReplyTimeouts OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of remote reply timeouts."
::= { phivDDCMPCircuitCountEntry 3 }

phivDDCMPCircuitLocalReplyTimeouts OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of local Reply timeouts."
::= { phivDDCMPCircuitCountEntry 4 }

phivDDCMPCircuitRmteBuffErrors OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of remote reply time out errors."
::= { phivDDCMPCircuitCountEntry 5 }

phivDDCMPCircuitLocalBuffErrors OBJECT-TYPE
SYNTAX PhivCounter (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of local buffer errors."
::= { phivDDCMPCircuitCountEntry 6 }



DECnet Phase IV MIB Working Group                              [Page 35]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivDDCMPCircuitSelectIntervalsElap OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION
"Selection intervals that have elapsed."
::= {phivDDCMPCircuitCountEntry 7 }

phivDDCMPCircuitSelectTimeouts OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of selection timeouts."
::= {phivDDCMPCircuitCountEntry 8 }

-- DDCMP Line Count Table

phivDDCMPLineCountTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivDDCMPLineCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"The DDCMP Line Count Table."
::= { ddcmp 3 }

phivDDCMPLineCountEntry OBJECT-TYPE
SYNTAX PhivDDCMPLineCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"There is one entry in the table for each line."
INDEX { phivDDCMPLineCountIndex } ::= { phivDDCMPLineCountTable 1 }

PhivDDCMPLineCountEntry ::=
SEQUENCE {
phivDDCMPLineCountIndex
INTEGER,
phivDDCMPLineCountDataErrsIn
PhivCounter (0..255),
phivDDCMPLineCountRmteStationErrs
PhivCounter (0..255),
phivDDCMPLineCountLocalStationErrs
PhivCounter (0..255)
}




DECnet Phase IV MIB Working Group                              [Page 36]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivDDCMPLineCountIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The line on which this entry's equivalence is effective. The interface identified by a particular value of this index is the same interface as identified by the same value of phivLineIndex. This value is the IfIndex."
::= { phivDDCMPLineCountEntry 1 }

phivDDCMPLineCountDataErrsIn OBJECT-TYPE
SYNTAX PhivCounter ( 0..255 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of data errors inbound."
::= { phivDDCMPLineCountEntry 2 }

phivDDCMPLineCountRmteStationErrs OBJECT-TYPE
SYNTAX PhivCounter ( 0..255 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of remote station errors."
::= { phivDDCMPLineCountEntry 3 }

phivDDCMPLineCountLocalStationErrs OBJECT-TYPE
SYNTAX PhivCounter ( 0..255 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of local station errors."
::= { phivDDCMPLineCountEntry 4 }

-- DDCMP Multipoint Circuit Control Group

-- The implementation of the DDCMP Multipoint Circuit Control -- Group is mandatory for all systems which support DDCMP -- multipoint control circuits.

phivControlSchedTimer OBJECT-TYPE SYNTAX INTEGER (50..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the number of milliseconds between recalculation of tributary polling priorities." DEFVAL { 200 } ::= { control 1 }


DECnet Phase IV MIB Working Group                              [Page 37]


RFC 1289                  DECnet Phase IV MIB              December 1991



phivControlDeadTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the number of milliseconds between polls of one of the set of dead tributaries." DEFVAL { 10000 } ::= { control 2 }

phivControlDelayTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the minimum number of milliseconds to delay between polls. The delay timer limits the effect of a very fast control station on slow tributaries."
::= { control 3 }

phivControlStreamTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the number of milliseconds a tributary or a half duplex remote station is allowed to hold the line.

NOTE: This parameter can also be applied to half-duplex lines of type DDCMP POINT." DEFVAL { 6000 } ::= { control 4 }

-- DDCMP Multipoint Circuit Control Parameters Table

phivControlParametersTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivControlParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"Information about control circuit parameters."


DECnet Phase IV MIB Working Group                              [Page 38]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { control 5 }

phivControlParametersEntry OBJECT-TYPE
SYNTAX PhivControlParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameters information about control circuits currently known." INDEX { phivControlCircuitIndex } ::= { phivControlParametersTable 1 }

PhivControlParametersEntry ::=
SEQUENCE {
phivControlCircuitIndex
INTEGER,
phivControlBabbleTimer
INTEGER (1..65535),
phivControlMaxBuffs
INTEGER (0..254),
phivControlMaxTransmits
INTEGER (1..255),
phivControlDyingBase
INTEGER (0..255),
phivControlDyingIncrement
INTEGER (0..255),
phivControlDeadThreshold
INTEGER (0..255),
phivControlDyingThreshold
INTEGER (0..255),
phivControlInactTreshold
INTEGER (0..255),
phivControlPollingState
INTEGER,
phivControlPollingSubState
INTEGER,
phivControlTransTimer
INTEGER (0..65535)
}
phivControlCircuitIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index value for each known multirpoint control circuit.
This is the same value as phivCircuitIndex."
::= { phivControlParametersEntry 1 }


DECnet Phase IV MIB Working Group                              [Page 39]


RFC 1289                  DECnet Phase IV MIB              December 1991



phivControlBabbleTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the number of milliseconds that a selected tributary or remote half-duplex station is allowed to transmit." DEFVAL { 6000 } ::= { phivControlParametersEntry 2 }

phivControlMaxBuffs OBJECT-TYPE
SYNTAX INTEGER (0..254) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of buffers the tributary can use from a common buffer pool. If not set, there is no common buffer pool and buffers are explicitly supplied by the higher level. Count is a decimal integer in the range 1-254."
::= { phivControlParametersEntry 3 }

phivControlMaxTransmits OBJECT-TYPE
SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of data messages that can be transmitted at one time. Count is a decimal integer in the range 1-255." DEFVAL { 4 } ::= { phivControlParametersEntry 4 }

phivControlDyingBase OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the base priority to which a tributary is reset each time it has been polled. A separate base can be set for each of the indicated polling states. Base is a decimal integer in the range 0-255. If not set, the defaults are: active, 255; inactive, 0; and dying, 0."
::= { phivControlParametersEntry 5 }



DECnet Phase IV MIB Working Group                              [Page 40]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivControlDyingIncrement OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the increment added to the tributary priority each time the scheduling timer expires. If not set, the defaults are: active, 0; inactive, 64; and dying, 16."
::= { phivControlParametersEntry 6 }

phivControlDeadThreshold OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the number of times to poll the active, inactive, or dying tributary before changing its polling state to dead because of receive timeouts. Count is a decimal integer in the range 0-255." DEFVAL { 8 } ::= { phivControlParametersEntry 7 }

phivControlDyingThreshold OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the number of times to poll the active or inactive tributary before changing its polling state to dying because of receive timeouts. Count is a decimal integer in the range 0-255." DEFVAL { 2 } ::= { phivControlParametersEntry 8 }

phivControlInactTreshold OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the number of times to poll the active tributary before changing its polling state to inactive because of no data response. Count is a decimal integer in the range 0-255." DEFVAL { 8 } ::= { phivControlParametersEntry 9 }



DECnet Phase IV MIB Working Group                              [Page 41]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivControlPollingState OBJECT-TYPE
SYNTAX INTEGER {
automatic (1), active (2), inactive (3), dying (4), dead (5) } ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the state of the tributary relative to the multipoint polling algorithm. If not set the default is AUTOMATIC. The possible states are:

AUTOMATIC

The tributary's state is allowed to vary according to the operation of the polling algorithm.

ACTIVE/INACTIVE/DYING/DEAD

The tributary is locked in the specified state.

NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155."
::= { phivControlParametersEntry 10 }

phivControlPollingSubState OBJECT-TYPE
SYNTAX INTEGER {
active (1), inactive (2), dying (3), dead (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the tributary's state as determined by the polling algorithm. This applies only when the polling state is AUTOMATIC and is read-only to Network Management. Polling-substate is one of ACTIVE, INACTIVE, DYING, or DEAD. It is displayed as a tag on the polling state, for example: AUTOMATIC-INACTIVE."
::= { phivControlParametersEntry 11 }



DECnet Phase IV MIB Working Group                              [Page 42]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivControlTransTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the number of milliseconds to delay between data message transmits. Milliseconds is a decimal integer in the range 0-65535." DEFVAL { 0 } ::= { phivControlParametersEntry 12 }

-- Ethernet Group

-- The implementation of the Ethernet Group is mandatory -- for all systems which support ethernet links.

-- Ethernet Parameters Table

phivEthLinkParametersTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivEthLinkParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"Information about ethernet link parameters."
::= { ethernet 1}

phivEthLinkParametersEntry OBJECT-TYPE
SYNTAX PhivEthLinkParametersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Parameter information about ethernet links currently known." INDEX { phivEthLinkIndex } ::= { phivEthLinkParametersTable 1 }

PhivEthLinkParametersEntry ::=
SEQUENCE {
phivEthLinkIndex
INTEGER,
phivEthDesigRouterNodeAddr
PhivAddr,
phivEthMaxRouters
INTEGER (0..255),
phivEthRouterPri
INTEGER (0..127),
phivEthHardwareAddr
OCTET STRING


DECnet Phase IV MIB Working Group                              [Page 43]


RFC 1289                  DECnet Phase IV MIB              December 1991


}
phivEthLinkIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The circuit over which this links information is collected. This is the same as phivCircuitIndex."
::= { phivEthLinkParametersEntry 1 }

phivEthDesigRouterNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION
"This value is the address of the designated router."
::= { phivEthLinkParametersEntry 2 }

phivEthMaxRouters OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION
"This parameter is the maximum number of routers (other
than the executor itself) allowed on the circuit by Routing for circuits that are owned by the executor node."
::= { phivEthLinkParametersEntry 3 }

phivEthRouterPri OBJECT-TYPE
SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION
"This parameter is the priority that this router is to
have in the selection of designated router for the circuit on circuits that are owned by the executor node." DEFVAL { 64 } ::= { phivEthLinkParametersEntry 4 }

phivEthHardwareAddr OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE (6) ) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter is the address that is associated with the line device hardware as seen by the DECnet Software. This value is not the same as ifPhysAddress."


DECnet Phase IV MIB Working Group                              [Page 44]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivEthLinkParametersEntry 5 }

-- Counters Group

-- The implementation of the Counters Group is mandatory for -- systems which only support DECnet style locking counters.

-- Counters Table

phivCountersCountTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivCountersCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"Information about ethernet link counters."
::= { counters 1 }

phivCountersCountEntry OBJECT-TYPE
SYNTAX PhivCountersCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Counter information about ethernet links currently known.." INDEX { phivCountersIndex } ::= { phivCountersCountTable 1 }

PhivCountersCountEntry ::=
SEQUENCE {
phivCountersIndex
INTEGER,
phivCountersCountBytesRecd
PhivCounter,
phivCountersCountBytesSent
PhivCounter,
phivCountersCountDataBlocksRecd
PhivCounter,
phivCountersCountDataBlocksSent
PhivCounter,
phivCountersCountEthUsrBuffUnav
PhivCounter (0..65535),
phivCountersCountMcastBytesRecd
PhivCounter,
phivCountersCountDataBlksRecd
PhivCounter,
phivCountersCountDataBlksSent


DECnet Phase IV MIB Working Group                              [Page 45]


RFC 1289                  DECnet Phase IV MIB              December 1991


PhivCounter,
phivCountersCountMcastBlksRecd
PhivCounter,
phivCountersCountBlksSentDef
PhivCounter,
phivCountersCountBlksSentSingleCol
PhivCounter,
phivCountersCountBlksSentMultCol
PhivCounter,
phivCountersCountSendFailure
PhivCounter,
phivCountersCountCollDetectFailure
PhivCounter (0..65535),
phivCountersCountReceiveFailure
PhivCounter (0..65535),
phivCountersCountUnrecFrameDest
PhivCounter (0..65535),
phivCountersCountDataOver
PhivCounter (0..65535),
phivCountersCountSysBuffUnav
PhivCounter (0..65535),
phivCountersCountUsrBuffUnav
PhivCounter (0..65535)
}
phivCountersIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The interface to which these counters apply. This is the same interface as identified by the same value of phivLineIndex. This value is the IfIndex."
::= { phivCountersCountEntry 1 }

phivCountersCountBytesRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of bytes received over this link."
::= { phivCountersCountEntry 2 }

phivCountersCountBytesSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of bytes sent over this link."


DECnet Phase IV MIB Working Group                              [Page 46]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivCountersCountEntry 3 }

phivCountersCountDataBlocksRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of data blocks received over this link."
::= { phivCountersCountEntry 4 }

phivCountersCountDataBlocksSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of data blocks sent over this link."
::= { phivCountersCountEntry 5 }

phivCountersCountEthUsrBuffUnav OBJECT-TYPE
SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Number of user buffer unavailable errors over this link."
::= { phivCountersCountEntry 6 }

phivCountersCountMcastBytesRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of multicast bytes received over this link."
::= { phivCountersCountEntry 7 }

phivCountersCountDataBlksRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of data blocks received over this link."
::= { phivCountersCountEntry 8 }

phivCountersCountDataBlksSent OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION


DECnet Phase IV MIB Working Group                              [Page 47]


RFC 1289                  DECnet Phase IV MIB              December 1991


"Number of data blocks sent over this link."
::= { phivCountersCountEntry 9 }

phivCountersCountMcastBlksRecd OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of multicast blocks received over this link."
::= { phivCountersCountEntry 10 }

phivCountersCountBlksSentDef OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of blocks sent, initially deferred over this link."
::= { phivCountersCountEntry 11 }

phivCountersCountBlksSentSingleCol OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION
"Number of blocks sent, single collision over this link."
::= { phivCountersCountEntry 12 }

phivCountersCountBlksSentMultCol OBJECT-TYPE
SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of blocks sent, multiple collisions over this link."
::= { phivCountersCountEntry 13 }

phivCountersCountSendFailure OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of send failures over this link."
::= { phivCountersCountEntry 14 }

phivCountersCountCollDetectFailure OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION "Number of collision detect check failures over this link."


DECnet Phase IV MIB Working Group                              [Page 48]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivCountersCountEntry 15 }

phivCountersCountReceiveFailure OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of receive failures over this link."
::= { phivCountersCountEntry 16 }

phivCountersCountUnrecFrameDest OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION "Number of unrecognized frame destinations over this link."
::= { phivCountersCountEntry 17 }

phivCountersCountDataOver OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of data overruns over this link."
::= { phivCountersCountEntry 18 }

phivCountersCountSysBuffUnav OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of system buffer unavailables over this link."
::= { phivCountersCountEntry 19 }

phivCountersCountUsrBuffUnav OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION
"Number of user buffer unavailables."
::= { phivCountersCountEntry 20 }




DECnet Phase IV MIB Working Group                              [Page 49]


RFC 1289                  DECnet Phase IV MIB              December 1991


-- Adjacency Group

-- The implementation of the Adjacency Group is mandatory for all -- conformant implementations of this memo.

phivAdjTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivAdjEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"The Adjacency Table."
::= { adjacency 1 }

phivAdjEntry OBJECT-TYPE
SYNTAX PhivAdjEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"There is one entry in the table for each adjacency."
INDEX { phivAdjCircuitIndex } ::= { phivAdjTable 1 }

PhivAdjEntry ::=
SEQUENCE {
phivAdjCircuitIndex
INTEGER,
phivAdjNodeAddr
PhivAddr,
phivAdjBlockSize
INTEGER,
phivAdjListenTimer
INTEGER (1..65535),
phivAdjCircuitEtherServPhysAddr
OCTET STRING,
phivAdjType
INTEGER,
phivAdjState
INTEGER,
phivAdjPriority
INTEGER,
phivAdjExecListenTimer
INTEGER (1..65535)
}

phivAdjCircuitIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION


DECnet Phase IV MIB Working Group                              [Page 50]


RFC 1289                  DECnet Phase IV MIB              December 1991


"A unique index value for each known circuit."
::= { phivAdjEntry 1 }

phivAdjNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION
"The address of the adjacent node."
::= { phivAdjEntry 2 }

phivAdjBlockSize OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter is the block size that was negotiated with the adjacent Routing layer during Routing initialization over a particular circuit. It includes the routing header, but excludes the data link header. This parameter is qualified by ADJACENT NODE."
::= { phivAdjEntry 3 }

phivAdjListenTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value determines the maximum number of seconds allowed to elapse before Routing receives some message (either a Hello message or a user message) from the adjacent node on the circuit. It was agreed during Routing initialization with the adjacent Routing layer. This parameter is qualified by ADJACENT NODE."
::= { phivAdjEntry 4 }

phivAdjCircuitEtherServPhysAddr OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE (6) ) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the Ethernet physical address of an adjacent node that is being serviced on this circuit. This parameter is a qualifier for SERVICE SUBSTATE."
::= { phivAdjEntry 5 }



DECnet Phase IV MIB Working Group                              [Page 51]


RFC 1289                  DECnet Phase IV MIB              December 1991


phivAdjType OBJECT-TYPE
SYNTAX INTEGER {
routing-III (1), nonrouting-III (2), area (3), routing-IV (4), nonrouting-IV (5) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the type of adjacency.

For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The routing-III and nonrouting-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155)"
::= { phivAdjEntry 6 }

phivAdjState OBJECT-TYPE
           SYNTAX INTEGER {
               initializing (1),          -- Ethernet one-way
               up (2),                    -- Ethernet two-way
run (3), -- The eight DDCMP/X.25 states circuit-rejected (4), data-link-start (5), routing-layer-initialize (6), routing-layer-verify (7), routing-layer-complete (8), off (9), halt (10) } ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the state of a router adjacency. On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjType) ROUTING IV or AREA, this variable is the state of the Ethernet Initialization Layer for this adjacency, and can have values INITIALIZING or UP. (See Section 9.1.1 of DECnet Phase IV Routing Layer Functional Specification.)

On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjType) NONROUTING IV, this variable will always take on the value UP.


DECnet Phase IV MIB Working Group                              [Page 52]


RFC 1289                  DECnet Phase IV MIB              December 1991



On adjacencies over a circuit of type (phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL, DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is the state of the Routing Layer Initialization Circuit State. (See section 7.3, ibid.) It can have values between RUN and HALT.

On adjacencies over a circuit of type (phivCircuitCommonType) OTHER, this variable may be used in a manner consistent with the Initialization Layer used on that circuit."
::= { phivAdjEntry 7 }

phivAdjPriority OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Priority assigned by the adjacent node for this circuit."
::= { phivAdjEntry 8 }

phivAdjExecListenTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only value determines the maximum number of seconds allowed to elapse before Routing receives some message (either a Hello message or a user message) from the adjacent node on the circuit. It was agreed during Routing initialization with the adjacent Routing layer."
::= { phivAdjEntry 9 }

-- Line Group

-- The implementation of the Line Group is mandatory for all -- conformant implementations of this memo.

phivLineTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"The Line Table."
::= { line 1 }


DECnet Phase IV MIB Working Group                              [Page 53]


RFC 1289                  DECnet Phase IV MIB              December 1991



phivLineEntry OBJECT-TYPE
SYNTAX PhivLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"There is one entry in the table for each line."
INDEX { phivLineIndex } ::= { phivLineTable 1 }

PhivLineEntry ::=
SEQUENCE {
phivLineIndex
INTEGER,
phivLineName
DisplayString,
phivLineState
INTEGER,
phivLineSubstate
INTEGER,
phivLineService
INTEGER,
phivLineDevice
DisplayString,
phivLineReceiveBuffs
INTEGER (0..65535),
phivLineProtocol
INTEGER,
phivLineServiceTimer
INTEGER (1..65535),
phivLineMaxBlock
INTEGER (1..65535)
}

phivLineIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The line on which this entry's equivalence is effective. This is the same as the IfIndex."
::= { phivLineEntry 1 }

phivLineName OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..16) ) ACCESS read-only STATUS mandatory DESCRIPTION


DECnet Phase IV MIB Working Group                              [Page 54]


RFC 1289                  DECnet Phase IV MIB              December 1991


"The name of the line on this row of the table."
::= { phivLineEntry 2 }

phivLineState OBJECT-TYPE
SYNTAX INTEGER {
on (1), off (2), service (3), cleared (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents Network Management operational state. NOTE that these values are incremented by one compared to the standard DECnet values."
::= { phivLineEntry 3 }

phivLineSubstate OBJECT-TYPE
SYNTAX INTEGER {
starting (1), reflecting (2), looping (3), loading (4), dumping (5), triggering (6), auto-service (7), auto-loading (8), auto-dumping (9), auto-triggering (10), synchronizing (11), failed (12), running (13) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the line's read-only Network Management substate. NOTE that these values are incremented by one compared to the standard DECnet values."
::= { phivLineEntry 4 }

phivLineService OBJECT-TYPE
SYNTAX INTEGER {
starting (1), reflecting (2), looping (3), other (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the line's read-only Network Management service. NOTE that these values are incremented by one compared to the standard DECnet values and OTHER is a new addition."


DECnet Phase IV MIB Working Group                              [Page 55]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivLineEntry 5 }

phivLineDevice OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..16) ) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the Physical Link device to be used on the line."
::= { phivLineEntry 6 }

phivLineReceiveBuffs OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the number of receive buffers reserved for the line. It is a decimal number in the range 0-65535. 0 is supported for those vendors that do not reserve buffers on a per line basis and use a pool of buffers that can be used by any line."
::= { phivLineEntry 7 }

phivLineProtocol OBJECT-TYPE
SYNTAX INTEGER {
ddcmp-point (1), ddcmp-control (2), ddcmp-tributary (3), reserved (4), ddcmp-dmc (5), lapb (6), ethernet (7), ci (8), qp2 (9), other (14), fddi (15) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the protocol used on the line device. Note that these values are incremented by one compared to the standard DECnet values."


DECnet Phase IV MIB Working Group                              [Page 56]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivLineEntry 8 }

phivLineServiceTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the amount of time in milliseconds allowed to elapse before a Data Link receive request completes while doing service operations."
::= { phivLineEntry 9 }

phivLineMaxBlock OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the Data Link maximum block size on the line."
::= { phivLineEntry 10 }

-- Non Broadcast Line Group

-- The implementation of the Non Broadcast Line Group is -- mandatory for all systems which implement non broadcast -- lines.

phivNonBroadcastTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivNonBroadcastEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"The Non Broadcast Table."
::= { nonBroadcastLine 1 }

phivNonBroadcastEntry OBJECT-TYPE
SYNTAX PhivNonBroadcastEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one entry in the table for each Non Broadcast line." INDEX { phivNonBroadcastIndex } ::= { phivNonBroadcastTable 1 }


DECnet Phase IV MIB Working Group                              [Page 57]


RFC 1289                  DECnet Phase IV MIB              December 1991



PhivNonBroadcastEntry ::=
SEQUENCE {
phivNonBroadcastIndex
INTEGER,
phivNonBroadcastController
INTEGER,
phivNonBroadcastDuplex
INTEGER,
phivNonBroadcastClock
INTEGER,
phivNonBroadcastRetransmitTimer
INTEGER (1..65535)
}
phivNonBroadcastIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Non Broadcast line on which this entry's equivalence is effective. This is the same value as the IfIndex."
::= { phivNonBroadcastEntry 1 }

phivNonBroadcastController OBJECT-TYPE
SYNTAX INTEGER {
normal (1), loopback (2), other (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the Physical Link hardware controller mode for the line device. The values for controller-mode are:

NORMAL For normal controller operating mode.

LOOPBACK For software controllable loopback of the controller. On those devices that can support this mode, it causes all transmitted messages to be looped back from within the controller itself. This is accomplished without any manual intervention other than the setting of this parameter value.



DECnet Phase IV MIB Working Group                              [Page 58]


RFC 1289                  DECnet Phase IV MIB              December 1991


OTHER indicates function is not supported
Note that these values are incremented by one compared to the standard DECnet values."
::= { phivNonBroadcastEntry 2 }

phivNonBroadcastDuplex OBJECT-TYPE
SYNTAX INTEGER {
full (1), half (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the Physical Link hardware duplex mode of the line device. The possible modes are:

FULL Full-duplex HALF Half-duplex

Note that these values are incremented by one compared to the standard DECnet values."
::= { phivNonBroadcastEntry 3 }

phivNonBroadcastClock OBJECT-TYPE
SYNTAX INTEGER {
external (1), internal (2), other (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value represents the Physical Link hardware clock mode for the line device. The values for clock-mode are:

INTERNAL For software controllable loopback use of the clock. On those devices that can support this mode, it causes the device to supply a clock signal such that a transmitted messages can be looped back from outside the device. This may require manual intervention other than the setting of this parameter value. For example, the operator may have to connect a loopback plug in place of the normal line.

EXTERNAL For normal clock operating mode, where the clock signal is supplied externally to the controller. Note that these values are incremented by one compared to the standard DECnet values."


DECnet Phase IV MIB Working Group                              [Page 59]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivNonBroadcastEntry 4 }

phivNonBroadcastRetransmitTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value represents number of milliseconds before the Data Link retransmits a block on the line. On half-duplex lines, this parameter is the select timer." DEFVAL { 3000 } ::= { phivNonBroadcastEntry 5 }

-- Area Parameters Group

-- The implementation of the Area Parameters Group is mandatory -- for all systems which implement level 2 routing.

phivAreaTable OBJECT-TYPE SYNTAX SEQUENCE OF PhivAreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information kept on all areas known to this unit."
::= { area 1 }

phivAreaEntry OBJECT-TYPE
SYNTAX PhivAreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION
"The area routing information."
INDEX { phivAreaNum } ::= { phivAreaTable 1 }

PhivAreaEntry ::=
SEQUENCE {
phivAreaNum
INTEGER,
phivAreaState
INTEGER,
phivAreaCost
Gauge,
phivAreaHops
INTEGER,
phivAreaNextNode


DECnet Phase IV MIB Working Group                              [Page 60]


RFC 1289                  DECnet Phase IV MIB              December 1991


PhivAddr,
phivAreaCircuitIndex
INTEGER
}
phivAreaNum OBJECT-TYPE
SYNTAX INTEGER (0..64) ACCESS read-only STATUS mandatory DESCRIPTION
"This value indicates the area number of this entry."
::= { phivAreaEntry 1 }

phivAreaState OBJECT-TYPE
SYNTAX INTEGER {
reachable (4), unreachable (5) } ACCESS read-only STATUS mandatory DESCRIPTION
"This value indicates the state of the area"
::= { phivAreaEntry 2 }

phivAreaCost OBJECT-TYPE
SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION
"The total cost over the current path to the
destination area. Cost is a value associated with using a circuit. Routing routes messages (data) along the path between 2 areas with the smallest cost."
::= { phivAreaEntry 3 }

phivAreaHops OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of hops to a destination area. A hop is the routing value representing the logical distance between two areas in network."
::= { phivAreaEntry 4 }

phivAreaNextNode OBJECT-TYPE
SYNTAX PhivAddr ACCESS read-only STATUS mandatory DESCRIPTION "The next node on the circuit used to get to the area under scrutiny."


DECnet Phase IV MIB Working Group                              [Page 61]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { phivAreaEntry 5 }

phivAreaCircuitIndex OBJECT-TYPE
SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION
"A unique index value for each known circuit."
::= { phivAreaEntry 6 }

-- Additional Area Parameters

phivAreaMaxCost OBJECT-TYPE SYNTAX INTEGER (1..1022) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum total path cost allowed from the executor to any other level 2 routing node. The AREA MAXIMUM COST number is decimal in the range 1-1022. This parameter is only applicable if the executor node is of type AREA."
::= { area 2 }

phivAreaMaxHops OBJECT-TYPE
SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of routing hops allowable from the executor to any other level 2 routing node. This parameter is only applicable if the executor node is of type AREA."
::= { area 3 }

phivRouteMaxArea OBJECT-TYPE
SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the largest area number and, therefore, number of areas that can be known about by the executor node's Routing. This parameter is only applicable if the executor node is of type AREA."


DECnet Phase IV MIB Working Group                              [Page 62]


RFC 1289                  DECnet Phase IV MIB              December 1991


::= { area 4 }

END
5.  Acknowledgements

This document is the result of work undertaken the by DECnet Phase IV MIB working group. In addition, the special contributions and comments of the following members are also acknowledged:

Chris Chiotasso, Sparticus Steven Hunter, National Energy Research Supercomputer Center, Lawrence Livermore National Laboratory
6.  References

Cerf, V., "IAB Recommendations for the Development of Internet Network Management Standards", RFC 1052, NRI, April 1988.

Rose M., and K. McCloghrie, "Structure and Identification of Management Information for TCP/IP-based internets", RFC 1155, Performance Systems International, Hughes LAN Systems, May 1990.

McCloghrie K., and M. Rose, "Management Information Base for Network Management of TCP/IP-based internets", RFC 1156, Hughes LAN Systems, Performance Systems International, May 1990.

Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple Network Management Protocol", RFC 1157, SNMP Research, Performance Systems International, Performance Systems International, MIT Laboratory for Computer Science, May 1990.

McCloghrie K., and M. Rose, Editors, "Management Information Base for Network Management of TCP/IP-based internets", RFC 1213, Performance Systems International, March 1991.

Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions", RFC 1212, Performance Systems International, Hughes LAN Systems, March 1991.

Cook, J., Editor, "Definitions of Managed Objects for the Ethernet- like Interface Types", RFC 1284, Chipcom Corporation, December 1991.

Digital Equipment Corporation, "DECnet-ULTRIX NCP Command Reference", Digital Equipment Corporation, Maynard, Massachusetts.

Digital Equipment Corporation, "DECnet-ULTRIX USE Guide", Digital Equipment Corporation, Maynard, Massachusetts. Digital Equipment Corporation, "DECnet DIGITAL Network Architecture, Network Management Functional Specification", Version 4.0.0. Digital Equipment Corporation, Maynard, Massachusetts, July 1983.


DECnet Phase IV MIB Working Group                              [Page 63]


RFC 1289                  DECnet Phase IV MIB              December 1991



Digital Equipment Corporation, "DECnet DIGITAL Network Architecture, Routing Layer Functional Specification", Version 2.0.0. Digital Equipment Corporation, Maynard, Massachusetts, May 1983.

Security Considerations

Security issues are not discussed in this memo.

Author's Address

Jon Saperia Digital Equipment Corporation 40 Old Bolton Road Stow, Massachusetts 01775-1215

Phone: 508-496-8333

EMail: saperia@enet.dec.com





























DECnet Phase IV MIB Working Group [Page 64]