[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

Tweet
This is a modified version of the Internet RFC suitable for machine-translating. Original version is available here: RFC1285

HISTORIC
Updated by: 1512
Network Working Group                                            J. Case
Request for Comments: 1285                   SNMP Research, Incorporated
                                                            January 1992


                    
FDDI Management Information Base

Status of this Memo

This memo is an extension to the SNMP MIB. This RFC specifies an IAB standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "IAB Official Protocol Standards" for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Table of Contents

1. Abstract .............................................. 1
2. The Network Management Framework....................... 1
3. Objects ............................................... 2
3.1 Format of Definitions ................................ 2
4. Overview .............................................. 3
4.1 Textual Conventions .................................. 3
5. Object Definitions .................................... 4
5.1 The SMT Group ........................................ 5
5.2 The MAC Group ........................................ 15
5.3 The PATH Group ....................................... 27
5.4 The PORT Group ....................................... 27
5.5 The ATTACHMENT Group ................................. 38
5.6 The Chip Set Group ................................... 42
6. Acknowledgements ...................................... 43
7. References ............................................ 45
Security Considerations................................... 46 Author's Address.......................................... 46
1.  Abstract

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP-based internets. In particular, it defines objects for managing devices which implement the FDDI.
2.  The Network Management Framework

The Internet-standard Network Management Framework consists of three components. They are: RFC 1155 which defines the SMI, the mechanisms used for describing and naming objects for the purpose of management. RFC 1212 defines a more concise description mechanism, which is wholly consistent with the SMI.
Case                                                            [Page 1]


RFC 1285                        FDDI MIB                    January 1992

RFC 1156 which defines MIB-I, the core set of managed objects for the Internet suite of protocols. RFC 1213, defines MIB-II, an evolution of MIB-I based on implementation experience and new operational requirements.

RFC 1157 which defines the SNMP, the protocol used for network access to managed objects.

The Framework permits new objects to be defined for the purpose of experimentation and evaluation.
3.  Objects

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the subset of Abstract Syntax Notation One (ASN.1) [5] defined in the SMI. In particular, each object has a name, a syntax, and an encoding. The name is an object identifier, an administratively assigned name, which specifies an object type. The object type together with an object instance serves to uniquely identify a specific instantiation of the object. For human convenience, we often use a textual string, termed the OBJECT DESCRIPTOR, to also refer to the object type.

The syntax of an object type defines the abstract data structure corresponding to that object type. The ASN.1 language is used for this purpose. However, the SMI [1] purposely restricts the ASN.1 constructs which may be used. These restrictions are explicitly made for simplicity.

The encoding of an object type is simply how that object type is represented using the object type's syntax. Implicitly tied to the notion of an object type's syntax and encoding is how the object type is represented when being transmitted on the network.

The SMI specifies the use of the basic encoding rules of ASN.1 [6], subject to the additional requirements imposed by the SNMP.
3.1.  Format of Definitions

Section 5 contains contains the specification of all object types contained in this MIB module. The object types are defined using the conventions defined in the SMI, as amended by the extensions specified in [7].
Case                                                            [Page 2]


RFC 1285                        FDDI MIB                    January 1992

4.  Overview

This document defines the managed objects for FDDI devices which are to be accessible via the Simple Network Management Protocol (SNMP). At present, this applies to these values of the ifType variable in the Internet-standard MIB:

fddi(15)

For these interfaces, the value of the ifSpecific variable in the MIB-II [4] has the OBJECT IDENTIFIER value:

fddi OBJECT IDENTIFIER ::= { transmission 15 }

The definitions of the objects presented here draws heavily from related work in the ANSI X3T9.5 committee and the SMT subcommittee of that committee [8]. In fact, the definitions of the managed objects in this document are, to the maximum extent possible, identical to those identified by the ANSI committee. The semantics of each managed object should be the same with syntactic changes made as necessary to recast the objects in terms of the Internet-standard SMI and MIB so as to be compatible with the SNMP. Examples of these syntactic changes include remapping booleans to enumerated integers, remapping bit strings to octet strings, and the like. In addition, the naming of the objects was changed to achieve compatibility.

These minimal syntactic changes with no semantic changes should allow implementations of SNMP manageable FDDI systems to share instrumentation with other network management schemes and thereby minimize implementation cost. In addition, the translation of information conveyed by managed objects from one network management scheme to another is eased by these shared definitions.

Only the essential variables, as indicated by their mandatory status in the ANSI specification were retained in this document. The importance of variables which have an optional status in the ANSI specification were perceived as being less widely accepted.
4.1.  Textual Conventions

Several new datatypes are introduced as a textual convention in this MIB document. These textual conventions enhance the readability of the document and ease comparisons with its ANSI counterpart. It should be noted that the introduction of the following textual conventions has no effect on either the syntax nor the semantics of any managed objects. The use of these is merely an artifact of the explanatory method used. Objects defined in terms of one of these methods are always encoded by means of the rules that define the primitive type. Hence, no changes to the SMI or the SNMP are necessary to accommodate these textual conventions which are adopted merely for the convenience of readers and writers in pursuit of the elusive goal of clear, concise, and unambiguous MIB documents.
Case                                                            [Page 3]


RFC 1285                        FDDI MIB                    January 1992

5.  Object Definitions

RFC1285-MIB DEFINITIONS ::= BEGIN

IMPORTS
Counter
FROM RFC1155-SMI
transmission
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;

-- This MIB module uses the extended OBJECT-TYPE macro as -- defined in [7].


-- this is the FDDI MIB module

fddi OBJECT IDENTIFIER ::= { transmission 15 }


-- textual conventions

FddiTime ::= INTEGER (0..2147483647) -- This data type specifies octet units of 80 nanoseconds as -- an integer value. It is used for Path Latency and -- Synchronous Bandwidth values. The encoding is normal -- integer representation (not twos complement).

FddiResourceId ::= INTEGER (0..65535) -- This data type is used to refer to an instance of a MAC, -- PORT, PATH, or ATTACHMENT Resource ID. Indexing begins -- at 1. Zero is used to indicate the absence of a resource.

FddiSMTStationIdType ::= OCTET STRING (SIZE (8)) -- The unique identifier for the FDDI station. This is a -- string of 8 octets, represented as -- X' yy yy xx xx xx xx xx xx' -- with the low order 6 octet (xx) from a unique IEEE -- assigned address. The high order two bits of the IEEE -- address, the group address bit and the administration bit -- (Universal/Local) bit should both be zero. The first two -- octets, the yy octets, are implementor-defined. -- -- The representation of the address portion of the station id -- is in the IEEE (ANSI/IEEE P802.1A) canonical notation for -- 48 bit addresses. The canonical form is a 6-octet string -- where the first octet contains the first 8 bits of the -- address, with the I/G(Individual/Group) address bit as the -- least significant bit and the U/L (Universal/Local) bit -- as the next more significant bit, and so on. Note that -- addresses in the ANSI FDDI standard SMT frames are -- represented in FDDI MAC order.
Case                                                            [Page 4]


RFC 1285                        FDDI MIB                    January 1992

FddiMACLongAddressType ::= OCTET STRING (SIZE (6)) -- The representation of long MAC addresses as management -- values is in the IEEE (ANSI/IEEE P802.1A) canonical -- notation for 48 bit addresses. The canonical form is a -- 6-octet string where the first octet contains the first 8 -- bits of the address, with the I/G (Individual/Group) -- address bit as the least significant bit and the U/L -- (Universal/Local) bit as the next more significant bit, -- and so on. Note that the addresses in the SMT frames are -- represented in FDDI MAC order.

-- groups in the FDDI MIB module

snmpFddiSMT OBJECT IDENTIFIER ::= { fddi 1 }

snmpFddiMAC OBJECT IDENTIFIER ::= { fddi 2 }

snmpFddiPATH OBJECT IDENTIFIER ::= { fddi 3 }

snmpFddiPORT OBJECT IDENTIFIER ::= { fddi 4 }

snmpFddiATTACHMENT OBJECT IDENTIFIER ::= { fddi 5 }

snmpFddiChipSets OBJECT IDENTIFIER ::= { fddi 6 }


-- the SMT group -- Implementation of the SMT group is mandatory for all -- systems which implement manageable FDDI subsystems.

snmpFddiSMTNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of SMT implementations (regardless of their current state) on this network management application entity. The value for this variable must remain constant at least from one re- initialization of the entity's network management system to the next re-initialization."


Case                                                            [Page 5]


RFC 1285                        FDDI MIB                    January 1992


::= { snmpFddiSMT 1 }


-- the SMT table

snmpFddiSMTTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiSMTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of SMT entries. The number of entries is given by the value of snmpFddiSMTNumber."
::= { snmpFddiSMT 2 }

snmpFddiSMTEntry OBJECT-TYPE
SYNTAX SnmpFddiSMTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An SMT entry containing information common to a given SMT." INDEX { snmpFddiSMTIndex } ::= { snmpFddiSMTTable 1 }

SnmpFddiSMTEntry ::=
SEQUENCE {
snmpFddiSMTIndex
INTEGER,
snmpFddiSMTStationId
FddiSMTStationIdType,
snmpFddiSMTOpVersionId
INTEGER,
snmpFddiSMTHiVersionId
INTEGER,
snmpFddiSMTLoVersionId
INTEGER,
snmpFddiSMTMACCt
INTEGER,
snmpFddiSMTNonMasterCt
INTEGER,
snmpFddiSMTMasterCt
INTEGER,


Case                                                            [Page 6]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiSMTPathsAvailable
INTEGER,
snmpFddiSMTConfigCapabilities
INTEGER,
snmpFddiSMTConfigPolicy
INTEGER,
snmpFddiSMTConnectionPolicy
INTEGER,
snmpFddiSMTTNotify
INTEGER,
snmpFddiSMTStatusReporting
INTEGER,
snmpFddiSMTECMState
INTEGER,
snmpFddiSMTCFState
INTEGER,
snmpFddiSMTHoldState
INTEGER,
snmpFddiSMTRemoteDisconnectFlag
INTEGER,
snmpFddiSMTStationAction
INTEGER
}

snmpFddiSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
::= { snmpFddiSMTEntry 1 }

snmpFddiSMTStationId OBJECT-TYPE
SYNTAX FddiSMTStationIdType -- OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION
"Uniquely identifies an FDDI station."
REFERENCE
"ANSI { fddiSMT 11 }"
::= { snmpFddiSMTEntry 2 }
Case                                                            [Page 7]


RFC 1285                        FDDI MIB                    January 1992
snmpFddiSMTOpVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The version that this station is using for its operation (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 13 }"
::= { snmpFddiSMTEntry 3 }

snmpFddiSMTHiVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The highest version of SMT that this station supports (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 14 }"
::= { snmpFddiSMTEntry 4 }

snmpFddiSMTLoVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The lowest version of SMT that this station supports (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 15 }"
::= { snmpFddiSMTEntry 5 }

snmpFddiSMTMACCt OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of MACs in the station or concentrator."
REFERENCE
"ANSI { fddiSMT 21 }"
::= { snmpFddiSMTEntry 6 }

snmpFddiSMTNonMasterCt OBJECT-TYPE
SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Non Master PORTs (A, B, or S PORTs) in the station or concentrator."


Case                                                            [Page 8]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiSMT 22 }"
::= { snmpFddiSMTEntry 7 }

snmpFddiSMTMasterCt OBJECT-TYPE
SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Master PORTs in a node. If the node is not a concentrator, the value is zero."
REFERENCE
"ANSI { fddiSMT 23 }"
::= { snmpFddiSMTEntry 8 }

snmpFddiSMTPathsAvailable OBJECT-TYPE
SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the PATH types available in the station.

The value is a sum. This value initially takes the value zero, then for each type of PATH that this node has available, 2 raised to a power is added to the sum. The powers are according to the following table:

Path Power
Primary 0
Secondary 1
Local 2

For example, a station having Primary and Local PATHs available would have a value of 5 (2**0 + 2**2)."
REFERENCE
"ANSI { fddiSMT 24 }"
::= { snmpFddiSMTEntry 9 }

snmpFddiSMTConfigCapabilities OBJECT-TYPE
SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates capabilities that are present in the node. If 'holdAvailable' is present, this indicates support of the optional Hold Function (refer to ANSI SMT 9.4.3.2). If 'CF-Wrap-AB' is present, this indicates that the WRAP_AB state is forced.


Case                                                            [Page 9]


RFC 1285                        FDDI MIB                    January 1992



The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table:

Policy Power
holdAvailable 0
CF-Wrap-AB 1 "
REFERENCE
"ANSI { fddiSMT 25 }"
::= { snmpFddiSMTEntry 10 }

snmpFddiSMTConfigPolicy OBJECT-TYPE
SYNTAX INTEGER (0..3) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the configuration policies currently enforced in the node (refer to ANSI SMT 9.4.3.2). The 'configurationHold' policy refers to the Hold flag, and should not be present only if the Hold function is supported. The 'CF-Wrap- AB' policy refers to the CF_Wrap_AB flag.

The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table:

Policy Power
configurationHold 0
CF-Wrap-AB 1 "
REFERENCE
"ANSI { fddiSMT 26 }"
::= { snmpFddiSMTEntry 11 }
Case                                                           [Page 10]


RFC 1285                        FDDI MIB                    January 1992
snmpFddiSMTConnectionPolicy OBJECT-TYPE
SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the connection policies enforced at the station. A station sets the corresponding policy for each of the connection types that it rejects. The letter designations, X and Y, in the 'rejectX-Y' names have the following significance: X represents the PC-Type of the local PORT and Y represents a PC-Neighbor in the evaluation of Connection-Policy (PC-Type, PC- Neighbor) that is done to determine the setting of T-Val(3) in the PC-Signaling sequence (refer to ANSI Section 9.6.3).

The value is a sum. This value initially takes the value zero, then for each of the connection policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table:

Policy Power
rejectA-A 0 rejectA-B 1 rejectA-S 2 rejectA-M 3 rejectB-A 4 rejectB-B 5 rejectB-S 6 rejectB-M 7 rejectS-A 8 rejectS-B 9 rejectS-S 10 rejectS-M 11 rejectM-A 12 rejectM-B 13 rejectM-S 14 rejectM-M 15

Implementors should note that the polarity of these bits is different in different places in an SMT system. Implementors should take appropriate care."
REFERENCE
"ANSI { fddiSMT 27 }"
::= { snmpFddiSMTEntry 12 }


Case                                                           [Page 11]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiSMTTNotify OBJECT-TYPE
SYNTAX INTEGER (2..30) ACCESS read-write STATUS mandatory DESCRIPTION "The timer used in the Neighbor Notification protocol, reported in seconds and ranging from 2 to 30 seconds (refer to ANSI SMT 8.3.1)."
REFERENCE
"ANSI { fddiSMT 29 }"
::= { snmpFddiSMTEntry 13 }

snmpFddiSMTStatusReporting OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the node implements the Status Reporting Protocol. This object is included for compatibility with products that were designed prior to the adoption of this standard."
REFERENCE
"ANSI { fddiSMT 30 }"
::= { snmpFddiSMTEntry 14 }

snmpFddiSMTECMState OBJECT-TYPE
SYNTAX INTEGER {
ec0(1), -- Out ec1(2), -- In ec2(3), -- Trace ec3(4), -- Leave ec4(5), -- Path_Test ec5(6), -- Insert ec6(7), -- Check ec7(8) -- Deinsert
}
ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current state of the ECM state machine (refer to ANSI SMT 9.5.2)."
REFERENCE
"ANSI { fddiSMT 41 }"
::= { snmpFddiSMTEntry 15 }

snmpFddiSMTCFState OBJECT-TYPE
SYNTAX INTEGER {
cf0(1), -- Isolated cf1(2), -- Wrap_S cf2(3), -- Wrap_A cf3(4), -- Wrap_B cf4(5), -- Wrap_AB cf5(6) -- Thru


Case                                                           [Page 12]


RFC 1285                        FDDI MIB                    January 1992


}
ACCESS read-only STATUS mandatory DESCRIPTION "The attachment configuration for the station or concentrator (refer to ANSI SMT 9.7.4.3)."
REFERENCE
"ANSI { fddiSMT 42 }"
::= { snmpFddiSMTEntry 16 }

snmpFddiSMTHoldState OBJECT-TYPE
SYNTAX INTEGER {
not-implemented(1), -- holding not implemented not-holding(2), holding-prm(3), -- holding on primary holding-sec(4) -- holding on secondary
}
ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the current state of the Hold function. The values are determined as follows: 'holding-prm' is set if the primary ring is operational and the Recovery Enable Flag is clear (NOT NO_Flag(primary) AND NOT RE_Flag). is set if the secondary ring is operational and the Recovery Enable Flag is clear (NOT NO_Flag(secondary) AND NOT RE_Flag). Ref 9.4.3. and 10.3.1. the primary or secondary, i.e., the Recovery Enable, RE_Flag, is set."
REFERENCE
"ANSI { fddiSMT 43 }"
::= { snmpFddiSMTEntry 17 }

snmpFddiSMTRemoteDisconnectFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating that the station was remotely disconnected from the network. A station requires a Connect Action (SM_CM_CONNECT.request (Connect)) to rejoin and clear the flag (refer to ANSI 6.4.5.2)."


Case                                                           [Page 13]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiSMT 44 }"
::= { snmpFddiSMTEntry 18 }

snmpFddiSMTStationAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following connect(2), disconnect(3), path-Test(4), self-Test(5)
}
ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows:
                      Other:          Results in a badValue error.

Connect: Generates an SM_CM_Connect.request(connect) signal to CMT indicating that the ECM State machine is to begin a connection sequence. The fddiSMTRemoteDisconnectFlag is cleared on the setting of this variable to 1. See ANSI Ref 9.3.1.1.

Disconnect: Generates an SM_CM_Connect.request(disconnect) signal to ECM and sets the fddiSMTRemoteDisconnectFlag. See ANSI Ref 9.3.1.1.

Path-Test: Initiates a station path test. The Path_Test variable (See ANSI Ref. 9.4.1) is set to Testing. The results of this action are not specified in this standard.

Self-Test: Initiates a station self test. The results of this action are not specified in this standard.

Attempts to set this object to all other values results in a badValue error. Agents may elect to return a badValue error on attempts to set this variable to path-Test(4) or self-Test(5)."


Case                                                           [Page 14]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiSMT 60 }"
::= { snmpFddiSMTEntry 19 }


-- the MAC group -- Implementation of the MAC Group is mandatory for all -- systems which implement manageable FDDI subsystems.

snmpFddiMACNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of MAC implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
::= { snmpFddiMAC 1 }


-- the MAC table

snmpFddiMACTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiMACEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of MAC entries. The number of entries is given by the value of snmpFddiMACNumber."
::= { snmpFddiMAC 2 }

snmpFddiMACEntry OBJECT-TYPE
SYNTAX SnmpFddiMACEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A MAC entry containing information common to a given MAC." INDEX { snmpFddiMACSMTIndex, snmpFddiMACIndex } ::= { snmpFddiMACTable 1 }

SnmpFddiMACEntry ::=
SEQUENCE {
snmpFddiMACSMTIndex
INTEGER,


Case                                                           [Page 15]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiMACIndex
INTEGER,
snmpFddiMACFrameStatusCapabilities
INTEGER,
snmpFddiMACTMaxGreatestLowerBound
FddiTime,
snmpFddiMACTVXGreatestLowerBound
FddiTime,
snmpFddiMACPathsAvailable
INTEGER,
snmpFddiMACCurrentPath
INTEGER,
snmpFddiMACUpstreamNbr
FddiMACLongAddressType,
snmpFddiMACOldUpstreamNbr
FddiMACLongAddressType,
snmpFddiMACDupAddrTest
INTEGER,
snmpFddiMACPathsRequested
INTEGER,
snmpFddiMACDownstreamPORTType
INTEGER,
snmpFddiMACSMTAddress
FddiMACLongAddressType,
snmpFddiMACTReq
FddiTime,
snmpFddiMACTNeg
FddiTime,
snmpFddiMACTMax
FddiTime,
snmpFddiMACTvxValue
FddiTime,
snmpFddiMACTMin
FddiTime,
snmpFddiMACCurrentFrameStatus
INTEGER,
snmpFddiMACFrameCts
Counter,
snmpFddiMACErrorCts
Counter,
snmpFddiMACLostCts
Counter,
snmpFddiMACFrameErrorThreshold
INTEGER,
snmpFddiMACFrameErrorRatio
INTEGER,
snmpFddiMACRMTState
INTEGER,


Case                                                           [Page 16]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiMACDaFlag
INTEGER,
snmpFddiMACUnaDaFlag
INTEGER,
snmpFddiMACFrameCondition
INTEGER,
snmpFddiMACChipSet
OBJECT IDENTIFIER,
snmpFddiMACAction
INTEGER
}


snmpFddiMACSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of the SMT index associated with this MAC."
::= { snmpFddiMACEntry 1 }

snmpFddiMACIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each MAC on the managed entity. The MAC identified by a particular value of this index is that identified by the same value of an ifIndex object instance. That is, if a MAC is associated with the interface whose value of ifIndex in the Internet-Standard MIB is equal to 5, then the value of snmpFddiMACIndex shall also equal 5. The value for each MAC must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
::= { snmpFddiMACEntry 2 }

snmpFddiMACFrameStatusCapabilities OBJECT-TYPE
SYNTAX INTEGER (0..1799) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the MAC's bridge and end- station capabilities for operating in a bridged FDDI network. The value is a sum. This value initially takes the value zero, then for each capability present, 2 raised to a power is added to the sum. The powers are according to the following table:


Case                                                           [Page 17]


RFC 1285                        FDDI MIB                    January 1992




Capability Power FSC-Type0 0 -- MAC repeats A/C indicators as received on -- copying with the intent to forward.

FSC-Type1 1 -- MAC sets C but not A on copying for -- forwarding.

FSC-Type2 2 -- MAC resets C and sets A on C set and -- A reset if the frame is not copied and the -- frame was addressed to this MAC

FSC-Type0-programmable 8 -- Type0 capability is programmable

FSC-Type1-programmable 9 -- Type1 capability is programmable

FSC-Type2-programmable 10 -- Type2 capability is programmable
"
REFERENCE
"ANSI { fddiMAC 11 }"
::= { snmpFddiMACEntry 3 }

snmpFddiMACTMaxGreatestLowerBound OBJECT-TYPE
SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "The greatest lower bound of T_Max supported for this MAC."
REFERENCE
"ANSI { fddiMAC 13 }"
::= { snmpFddiMACEntry 4 }

snmpFddiMACTVXGreatestLowerBound OBJECT-TYPE
SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The greatest lower bound of TVX supported for this MAC."


Case                                                           [Page 18]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiMAC 14 }"
::= { snmpFddiMACEntry 5 }

snmpFddiMACPathsAvailable OBJECT-TYPE
SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the PATH types available for this MAC.

The value is a sum. This value initially takes the value zero, then for each type of PATH that this MAC has available, 2 raised to a power is added to the sum. The powers are according to the following table:

Path Power
Primary 0
Secondary 1
Local 2 "
REFERENCE
"ANSI { fddiMAC 22 }"
::= { snmpFddiMACEntry 6 }

snmpFddiMACCurrentPath OBJECT-TYPE
SYNTAX INTEGER {
unknown(1), primary(2), secondary(4), local(8), isolated(16)
}
ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the association of the MAC with a station PATH."
REFERENCE
"ANSI { fddiMAC 23 }"
::= { snmpFddiMACEntry 7 }

snmpFddiMACUpstreamNbr OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown."


Case                                                           [Page 19]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiMAC 24 }"
::= { snmpFddiMACEntry 8 }

snmpFddiMACOldUpstreamNbr OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The previous value of the MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown."
REFERENCE
"ANSI { fddiMAC 26 }"
::= { snmpFddiMACEntry 9 }

snmpFddiMACDupAddrTest OBJECT-TYPE
SYNTAX INTEGER { none(1), pass(2), fail(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Duplicate Address Test flag, Dup_Addr_Test (refer to ANSI 8.3.1)."
REFERENCE
"ANSI { fddiMAC 29 }"
::= { snmpFddiMACEntry 10 }

snmpFddiMACPathsRequested OBJECT-TYPE
SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates PATH(s) desired for this MAC.

The value is a sum which represents the individual PATHs that are desired. This value initially takes the value zero, then for each type of PATH that this node is, 2 raised to a power is added to the sum. The powers are according to the following table:


Case                                                           [Page 20]


RFC 1285                        FDDI MIB                    January 1992



Path Power
Primary 0
Secondary 1
Local 2
Isolated 3

The precedence order is primary, secondary, local, and then isolated if multiple PATHs are desired are set."
REFERENCE
"ANSI { fddiMAC 32 }"
::= { snmpFddiMACEntry 11 }

snmpFddiMACDownstreamPORTType OBJECT-TYPE
SYNTAX INTEGER { a(1), b(2), s(3), m(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the PC-Type of the first port that is downstream of this MAC (the exit port)."
REFERENCE
"ANSI { fddiMAC 33 }"
::= { snmpFddiMACEntry 12 }

snmpFddiMACSMTAddress OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The 48 bit individual address of the MAC used for SMT frames."
REFERENCE
"ANSI { fddiMAC 41 }"
::= { snmpFddiMACEntry 13 }

snmpFddiMACTReq OBJECT-TYPE
SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "The value of T-Req (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)."
REFERENCE


Case                                                           [Page 21]


RFC 1285                        FDDI MIB                    January 1992


"ANSI { fddiMAC 51 }"
::= { snmpFddiMACEntry 14 }

snmpFddiMACTNeg OBJECT-TYPE
SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Neg (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)."
REFERENCE
"ANSI { fddiMAC 52 }"
::= { snmpFddiMACEntry 15 }

snmpFddiMACTMax OBJECT-TYPE
SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Max (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)."
REFERENCE
"ANSI { fddiMAC 53 }"
::= { snmpFddiMACEntry 16 }

snmpFddiMACTvxValue OBJECT-TYPE
SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of TvxValue (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)."
REFERENCE
"ANSI { fddiMAC 54 }"
::= { snmpFddiMACEntry 17 }

snmpFddiMACTMin OBJECT-TYPE
SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Min (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)."
REFERENCE
"ANSI { fddiMAC 55 }"
::= { snmpFddiMACEntry 18 }




Case                                                           [Page 22]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiMACCurrentFrameStatus OBJECT-TYPE
SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the MAC's operational frame status setting functionality.

The value is a sum. This value initially takes the value zero, then for each functionality present, 2 raised to a power is added to the sum. The powers are according to the following table:

Functionality Power
FSC-Type0 0 -- MAC repeats A/C indicators as received

FSC-Type1 1 -- MAC sets C but not A on copying for -- forwarding

FSC-Type2 2 -- MAC resets C and sets A on C set and A -- reset if frame is not copied
"
REFERENCE
"ANSI { fddiMAC 63 }"
::= { snmpFddiMACEntry 19 }

snmpFddiMACFrameCts OBJECT-TYPE
SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION
"Frame_Ct (refer to ANSI MAC 2.2.1)."
REFERENCE
"ANSI { fddiMAC 71 }"
::= { snmpFddiMACEntry 20 }

snmpFddiMACErrorCts OBJECT-TYPE
SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION
"Error_Ct (refer to ANSI MAC 2.2.1)."
REFERENCE
"ANSI { fddiMAC 81 }"
::= { snmpFddiMACEntry 21 }


Case                                                           [Page 23]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiMACLostCts OBJECT-TYPE
SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION
"Lost_Ct (refer to ANSI MAC 2.2.1)."
REFERENCE
"ANSI { fddiMAC 82 }"
::= { snmpFddiMACEntry 22 }

snmpFddiMACFrameErrorThreshold OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A threshold for determining when a MAC Condition report should be generated. The condition is true when the ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16. exceeds the threshold. It is used to determine when a station has an unacceptable frame error threshold. The sampling algorithm is implementation dependent. Any attempt to set this variable to a value of less than one shall result in a badValue error. Those who are familiar with the SNMP management framework will recognize that thresholds are not in keeping with the SNMP philosophy. However, this variable is supported by underlying SMT implementations already and maintaining this threshold should not pose an undue additional burden on SNMP agent implementors."
REFERENCE
"ANSI { fddiMAC 95 }"
::= { snmpFddiMACEntry 23 }

snmpFddiMACFrameErrorRatio OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the actual ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16."
REFERENCE
"ANSI { fddiMAC 96 }"
::= { snmpFddiMACEntry 24 }


Case                                                           [Page 24]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiMACRMTState OBJECT-TYPE
SYNTAX INTEGER {
rm0(1), -- Isolated rm1(2), -- Non_Op rm2(3), -- Ring_Op rm3(4), -- Detect rm4(5), -- Non_Op_Dup rm5(6), -- Ring_Op_Dup rm6(7), -- Directed rm7(8) -- Trace
}
ACCESS read-only STATUS mandatory DESCRIPTION
"Indicates the current state of the Ring
Management state machine (refer to ANSI Section
10)."
REFERENCE
"ANSI { fddiMAC 111 }"
::= { snmpFddiMACEntry 25 }

snmpFddiMACDaFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The RMT flag Duplicate Address Flag, DA_Flag (refer to ANSI 10.3.1.2)."
REFERENCE
"ANSI { fddiMAC 112 }"
::= { snmpFddiMACEntry 26 }

snmpFddiMACUnaDaFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag set when the upstream neighbor reports a duplicate address condition. Reset when the condition clears."
REFERENCE
"ANSI { fddiMAC 113 }"
::= { snmpFddiMACEntry 27 }

snmpFddiMACFrameCondition OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the MAC Condition is active when set. Cleared when the condition clears and on power up."


Case                                                           [Page 25]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiMAC 114 }"
::= { snmpFddiMACEntry 28 }

snmpFddiMACChipSet OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the hardware chip(s) which is (are) principally responsible for the implementation of the MAC function. A few OBJECT IDENTIFIERS are identified elsewhere in this memo. For those The assignment of additional OBJECT IDENTIFIERs to various types of hardware chip sets is managed by the IANA. For example, vendors whose chip sets are not defined in this memo may request a number from the Internet Assigned Numbers Authority (IANA) which indicates the assignment of a enterprise specific subtree which, among other things, may be used to allocate OBJECT IDENTIFIER assignments for that enterprise's chip sets. Similarly, in the absence of an appropriately assigned OBJECT IDENTIFIER in this memo or in an enterprise specific subtree of a chip vendor, a board or system vendor can request a number for a subtree from the IANA and make an appropriate assignment. It is desired that, whenever possible, the same OBJECT IDENTIFIER be used for all chips of a given type. Consequently, the assignment made in this memo for a chip, if any, should be used in preference to any other assignment and the assignment made by the chip manufacturer, if any, should be used in preference to assignments made by users of those chips. If the hardware chip set is unknown, the object identifier

unknownChipSet OBJECT IDENTIFIER ::= { 0 0 }

is returned. Note that unknownChipSet is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value."


Case                                                           [Page 26]


RFC 1285                        FDDI MIB                    January 1992


::= { snmpFddiMACEntry 29 }

snmpFddiMACAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following enableLLCService(2), disableLLCService(3), connectMAC(4), disconnectMAC(5)
}
ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows:

Other: Results in a badValue
error.

enableLLCService: enables MAC service to
higher layers.

disableLLCService: disables MAC service to
higher layers.

connectMAC: connect this MAC in
station.
                      disconnectMAC:          disconnect this MAC in
                                              station.

Attempts to set this object to all other values results in a badValue error."
REFERENCE
"ANSI { fddiMAC 130 }"
::= { snmpFddiMACEntry 30 }


-- the PATH group

-- the PATH group is empty for now and shall remain so until -- the ANSI community sorts out their PATH group


-- the PORT group -- Implementation of the PORT group is mandatory for all -- systems which implement manageable FDDI subsystems.


Case                                                           [Page 27]


RFC 1285                        FDDI MIB                    January 1992



snmpFddiPORTNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of PORT implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
::= { snmpFddiPORT 1 }


-- the PORT table

snmpFddiPORTTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiPORTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PORT entries. The number of entries is given by the value of snmpFddiPORTNumber."
::= { snmpFddiPORT 2 }

snmpFddiPORTEntry OBJECT-TYPE
SYNTAX SnmpFddiPORTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A PORT entry containing information common to a given PORT." INDEX { snmpFddiPORTSMTIndex, snmpFddiPORTIndex } ::= { snmpFddiPORTTable 1 }

SnmpFddiPORTEntry ::=
SEQUENCE {
snmpFddiPORTSMTIndex
INTEGER,
snmpFddiPORTIndex
INTEGER,
snmpFddiPORTPCType
INTEGER,
snmpFddiPORTPCNeighbor
INTEGER,
snmpFddiPORTConnectionPolicies


Case                                                           [Page 28]


RFC 1285                        FDDI MIB                    January 1992


INTEGER,
snmpFddiPORTRemoteMACIndicated
INTEGER,
snmpFddiPORTCEState
INTEGER,
snmpFddiPORTPathsRequested
INTEGER,
snmpFddiPORTMACPlacement
FddiResourceId,
snmpFddiPORTAvailablePaths
INTEGER,
snmpFddiPORTMACLoopTime
FddiTime,
snmpFddiPORTTBMax
FddiTime,
snmpFddiPORTBSFlag
INTEGER,
snmpFddiPORTLCTFailCts
Counter,
snmpFddiPORTLerEstimate
INTEGER,
snmpFddiPORTLemRejectCts
Counter,
snmpFddiPORTLemCts
Counter,
snmpFddiPORTLerCutoff
INTEGER,
snmpFddiPORTLerAlarm
INTEGER,
snmpFddiPORTConnectState
INTEGER,
snmpFddiPORTPCMState
INTEGER,
snmpFddiPORTPCWithhold
INTEGER,
snmpFddiPORTLerCondition
INTEGER,
snmpFddiPORTChipSet
OBJECT IDENTIFIER,
snmpFddiPORTAction
INTEGER
}

snmpFddiPORTSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of the SMT index associated with this PORT."


Case                                                           [Page 29]


RFC 1285                        FDDI MIB                    January 1992


::= { snmpFddiPORTEntry 1 }

snmpFddiPORTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each PORT within a given SMT. Its value ranges between 1 and the sum of the values of snmpFddiSMTNonMasterCt { snmpFddiSMTEntry 6 } and snmpFddiSMTMasterCt { snmpFddiSMTEntry 7 } on the given SMT. The value for each PORT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
::= { snmpFddiPORTEntry 2 }

snmpFddiPORTPCType OBJECT-TYPE
SYNTAX INTEGER { a(1), b(2), s(3), m(4) } ACCESS read-only STATUS mandatory DESCRIPTION "PC_Type (refer to ANSI SMT 9.2.2 and ANSI SMT 9.6.3.2)."
REFERENCE
"ANSI { fddiPORT 12 }"
::= { snmpFddiPORTEntry 3 }

snmpFddiPORTPCNeighbor OBJECT-TYPE
SYNTAX INTEGER { a(1), b(2), s(3), m(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The type (PC_Neighbor) of the remote PORT that is determined in PC_Signaling in R_Val (1,2) (refer to ANSI SMT 9.6.3.2)."
REFERENCE
"ANSI { fddiPORT 13 }"
::= { snmpFddiPORTEntry 4 }

snmpFddiPORTConnectionPolicies OBJECT-TYPE
SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the node's PORT policies. Pc-MAC-LCT, Pc-MAC-Loop, and Pc-MAC-Placement indicate how the respective PC Signaling Capability flags should be set (refer to ANSI SMT 9.4.3.2).


Case                                                           [Page 30]


RFC 1285                        FDDI MIB                    January 1992



The value is a sum. This value initially takes the value zero, then for each PORT policy, 2 raised to a power is added to the sum. The powers are according to the following table:

Policy Power
Pc-MAC-LCT 0
Pc-MAC-Loop 1
Pc-MAC-Placement 2 "
REFERENCE
"ANSI { fddiPORT 14 }"
::= { snmpFddiPORTEntry 5 }

snmpFddiPORTRemoteMACIndicated OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R_Val (9) (refer to ANSI SMT 9.6.3.2)."
REFERENCE
"ANSI { fddiPORT 15 }"
::= { snmpFddiPORTEntry 6 }

snmpFddiPORTCEState OBJECT-TYPE
SYNTAX INTEGER {
ce0(1), -- Isolated ce1(2), -- Insert_P ce2(3), -- Insert_S ce3(4), -- Insert_X ce4(5) -- Local
}
ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current state of PORT's Configuration Element (CE) (refer to ANSI 9.7.5). Note that this value represents the Current Path information for this PORT."
REFERENCE
"ANSI { fddiPORT 16 }"


Case                                                           [Page 31]


RFC 1285                        FDDI MIB                    January 1992


::= { snmpFddiPORTEntry 7 }

snmpFddiPORTPathsRequested OBJECT-TYPE
SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the desired association(s) of the port with a station PATH. The 'Primary' Path is the default. The value of 'Secondary' is only meaningful for S (slave) or M (master) PORT PC-Types. This value effects the setting of the CF_Insert_S, and CF_Insert_L flags (refer to ANSI Section 9.4.3). If the 'Primary' PATH is present, then the Primary PATH (the default PATH) is selected. If the 'Secondary' PATH is present and the 'Primary' PATH is not present, then the CF_Insert_S flag is set. If the 'Local' PATH is sent and neither the 'Primary' or 'Secondary' PATHs are sent, then the CF_Insert_L flag is set.

The value is a sum. This value initially takes the value zero, then for each type of PATH desired, 2 raised to a power is added to the sum. The powers are according to the following table:

Path Power
Primary 0
Secondary 1
Local 2
Isolated 3 "
REFERENCE
"ANSI { fddiPORT 17 }"
::= { snmpFddiPORTEntry 8 }

snmpFddiPORTMACPlacement OBJECT-TYPE
SYNTAX FddiResourceId -- INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the upstream MAC, if any, that is associated with the PORT. The value shall be zero if there is no MAC associated with the PORT. Otherwise, the value shall be equal to the value of snmpFddiMACIndex associated with the MAC."
REFERENCE
"ANSI { fddiPORT 18 }"
::= { snmpFddiPORTEntry 9 }


Case                                                           [Page 32]


RFC 1285                        FDDI MIB                    January 1992


snmpFddiPORTAvailablePaths OBJECT-TYPE
SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the PATH types available for M and S PORTs.

The value is a sum. This value initially takes the value zero, then for each type of PATH that this port has available, 2 raised to a power is added to the sum. The powers are according to the following table:

Path Power
Primary 0
Secondary 1
Local 2 "
REFERENCE
"ANSI { fddiPORT 19 }"
::= { snmpFddiPORTEntry 10 }

snmpFddiPORTMACLoopTime OBJECT-TYPE
SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "Time for the optional MAC Local Loop, T_Next(9), which is greater-than or equal-to 200 milliseconds (refer to ANSI SMT 9.4.4.2.3)."
REFERENCE
"ANSI { fddiPORT 21 }"
::= { snmpFddiPORTEntry 11 }

snmpFddiPORTTBMax OBJECT-TYPE
SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION
"TB_Max (refer to ANSI SMT 9.4.4.2.1)."
REFERENCE
"ANSI { fddiPORT 32 }"
::= { snmpFddiPORTEntry 12 }

snmpFddiPORTBSFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Break State, BS_Flag (refer to ANSI SMT 9.4.3.4)."


Case                                                           [Page 33]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiPORT 33 }"
::= { snmpFddiPORTEntry 13 }

snmpFddiPORTLCTFailCts OBJECT-TYPE
SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the consecutive times the link confidence test (LCT) has failed during connection management (refer to ANSI 9.4.1)."
REFERENCE
"ANSI { fddiPORT 42 }"
::= { snmpFddiPORTEntry 14 }

snmpFddiPORTLerEstimate OBJECT-TYPE
SYNTAX INTEGER (4..15) ACCESS read-only STATUS mandatory DESCRIPTION "A long term average link error rate. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent of the estimate."
REFERENCE
"ANSI { fddiPORT 51 }"
::= { snmpFddiPORTEntry 15 }

snmpFddiPORTLemRejectCts OBJECT-TYPE
SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A link error monitoring count of the times that a link has been rejected."
REFERENCE
"ANSI { fddiPORT 52 }"
::= { snmpFddiPORTEntry 16 }

snmpFddiPORTLemCts OBJECT-TYPE
SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The aggregate link error monitor error count, set to zero only on station power_up."


Case                                                           [Page 34]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiPORT 53 }"
::= { snmpFddiPORTEntry 17 }

snmpFddiPORTLerCutoff OBJECT-TYPE
SYNTAX INTEGER (4..15) ACCESS read-write STATUS mandatory DESCRIPTION "The link error rate estimate at which a link connection will be broken. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent."
REFERENCE
"ANSI { fddiPORT 58 }"
::= { snmpFddiPORTEntry 18 }

snmpFddiPORTLerAlarm OBJECT-TYPE
SYNTAX INTEGER (4..15) ACCESS read-write STATUS mandatory DESCRIPTION "The link error rate estimate at which a link connection will generate an alarm. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent of the estimate."
REFERENCE
"ANSI { fddiPORT 59 }"
::= { snmpFddiPORTEntry 19 }

snmpFddiPORTConnectState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1), connecting(2), standby(3), active(4)
}
ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are:



Case                                                           [Page 35]


RFC 1285                        FDDI MIB                    January 1992


disabled: (PC0:Off, PC9:Maint)
                      connecting: (PC1(Break) || PC3 (Connect) || PC4
                      (Next)                 || PC5 (Signal) || PC6
                      (Join) || PC7 (Verify))             &&
                      (PC_Withhold = None)

standby: (NOT PC_Withhold == None)
                          active: (PC2:Trace || PC8:Active) "
              REFERENCE
"ANSI { fddiPORT 61 }"
::= { snmpFddiPORTEntry 20 }

snmpFddiPORTPCMState OBJECT-TYPE
SYNTAX INTEGER {
pc0(1), -- Off pc1(2), -- Break pc2(3), -- Trace pc3(4), -- Connect pc4(5), -- Next pc5(6), -- Signal pc6(7), -- Join pc7(8), -- Verify pc8(9), -- Active pc9(10) -- Maint
}
ACCESS read-only STATUS mandatory DESCRIPTION
"(refer to SMT 9.6.2)."
REFERENCE
"ANSI { fddiPORT 62 }"
::= { snmpFddiPORTEntry 21 }

snmpFddiPORTPCWithhold OBJECT-TYPE
SYNTAX INTEGER { none(1), m-m(2), other(3) } ACCESS read-only STATUS mandatory DESCRIPTION
"PC_Withhold, (refer to ANSI SMT 9.4.1)."
REFERENCE
"ANSI { fddiPORT 63 }"
::= { snmpFddiPORTEntry 22 }

snmpFddiPORTLerCondition OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable is set to true whenever LerEstimate is less than or equal to LerAlarm."


Case                                                           [Page 36]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiPORT 64 }"
::= { snmpFddiPORTEntry 23 }

snmpFddiPORTChipSet OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the hardware chip(s) which is (are) principally responsible for the implementation of the PORT (PHY) function. A few OBJECT IDENTIFIERS are identified elsewhere in this memo. For those The assignment of additional OBJECT IDENTIFIERs to various types of hardware chip sets is managed by the IANA. For example, vendors whose chip sets are not defined in this memo may request a number from the Internet Assigned Numbers Authority (IANA) which indicates the assignment of a enterprise specific subtree which, among other things, may be used to allocate OBJECT IDENTIFIER assignments for that enterprise's chip sets. Similarly, in the absence of an appropriately assigned OBJECT IDENTIFIER in this memo or in an enterprise specific subtree of a chip vendor, a board or system vendor can request a number for a subtree from the IANA and make an appropriate assignment. It is desired that, whenever possible, the same OBJECT IDENTIFIER be used for all chips of a given type. Consequently, the assignment made in this memo for a chip, if any, should be used in preference to any other assignment and the assignment made by the chip manufacturer, if any, should be used in preference to assignments made by users of those chips. If the hardware chip set is unknown, the object identifier

unknownChipSet OBJECT IDENTIFIER ::= { 0 0 }

is returned. Note that unknownChipSet is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value."


Case                                                           [Page 37]


RFC 1285                        FDDI MIB                    January 1992


::= { snmpFddiPORTEntry 24 }

snmpFddiPORTAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following maintPORT(2), enablePORT(3), disablePORT(4), startPORT(5), stopPORT(6)
}
ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows:
                      Other:          Results in a badValue error.

maintPORT: Signal PC_Maint

enablePORT: Signal PC_Enable

disablePORT: Signal PC_Disable

startPORT: Signal PC_Start

stopPORT: Signal PC_Stop

Signals cause an SM_CM_CONTROL.request service to be generated with a control_action of `Signal' and the `variable' parameter set with the appropriate value (i.e., PC_Maint, PC_Enable, PC_Disable, PC_Start, PC_Stop). Ref. ANSI SMT Section 9.3.2.

Attempts to set this object to all other values results in a badValue error."
REFERENCE
"ANSI { fddiPORT 70 }"
::= { snmpFddiPORTEntry 25 }


-- the ATTACHMENT group -- Implementation of the ATTACHMENT group is mandatory for -- all systems which implement manageable FDDI subsystems. snmpFddiATTACHMENTNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of attachments (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."



Case                                                           [Page 38]


RFC 1285                        FDDI MIB                    January 1992


::= { snmpFddiATTACHMENT 1 }


-- the ATTACHMENT table

snmpFddiATTACHMENTTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiATTACHMENTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of ATTACHMENT entries. The number of entries is given by the value of snmpFddiATTACHMENTNumber."
::= { snmpFddiATTACHMENT 2 }

snmpFddiATTACHMENTEntry OBJECT-TYPE
SYNTAX SnmpFddiATTACHMENTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An ATTACHMENT entry containing information common to a given set of ATTACHMENTs.

The ATTACHMENT Resource represents a PORT or a pair of PORTs plus the optional associated optical bypass that are managed as a functional unit. Because of its relationship to the PORT Objects, there is a natural association of ATTACHMENT Resource Indices to the PORT Indices. The resource index for the ATTACHMENT is equal to the associated PORT index for 'single-attachment' and 'concentrator' type snmpFddiATTACHMENTClasses. For 'dual-attachment' Classes, the ATTACHMENT Index is the PORT Index of the A PORT of the A/B PORT Pair that represents the ATTACHMENT."
INDEX { snmpFddiATTACHMENTSMTIndex,
snmpFddiATTACHMENTIndex }


Case                                                           [Page 39]


RFC 1285                        FDDI MIB                    January 1992


::= { snmpFddiATTACHMENTTable 1 }

SnmpFddiATTACHMENTEntry ::=
SEQUENCE {
snmpFddiATTACHMENTSMTIndex
INTEGER,
snmpFddiATTACHMENTIndex
INTEGER,
snmpFddiATTACHMENTClass
INTEGER,
snmpFddiATTACHMENTOpticalBypassPresent
INTEGER,
snmpFddiATTACHMENTIMaxExpiration
FddiTime,
snmpFddiATTACHMENTInsertedStatus
INTEGER,
snmpFddiATTACHMENTInsertPolicy
INTEGER
}

snmpFddiATTACHMENTSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of the SMT index associated with this ATTACHMENT."
::= { snmpFddiATTACHMENTEntry 1 }

snmpFddiATTACHMENTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each ATTACHMENT on a given SMT. Its value ranges between 1 and the sum of the values of snmpFddiSMTNonMasterCt { snmpFddiSMTEntry 6 } and snmpFddiSMTMasterCt { snmpFddiSMTEntry 7 } on the given SMT. The value for each ATTACHMENT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
::= { snmpFddiATTACHMENTEntry 2 }

snmpFddiATTACHMENTClass OBJECT-TYPE
SYNTAX INTEGER {
single-attachment(1), dual-attachment(2), concentrator(3)


Case                                                           [Page 40]


RFC 1285                        FDDI MIB                    January 1992


}
ACCESS read-only STATUS mandatory DESCRIPTION "The Attachment class. This represents a PORT or a pair of PORTs plus the associated optional optical bypass that are managed as a functional unit. The PORT associations are the following:

single-attachment - S PORTs
dual-attachment - A/B PORT Pairs
concentrator - M PORTs "
REFERENCE
"ANSI { fddiATTACHMENT 11 }"
::= { snmpFddiATTACHMENTEntry 3 }

snmpFddiATTACHMENTOpticalBypassPresent OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this value is false for 'single- attachment' and { snmpFddiATTACHMENT 11 }. Correct operation of CMT for single-attachment and concentrator attachments requires that a bypass function must not loopback the network side of the MIC, but only the node side."
REFERENCE
"ANSI { fddiATTACHMENT 12 }"
::= { snmpFddiATTACHMENTEntry 4 }

snmpFddiATTACHMENTIMaxExpiration OBJECT-TYPE
SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "I_Max (refer to ANSI SMT 9.4.4.2.1). It is recognized that some currently deployed systems do not implement an optical bypass. Systems which do not implement optical bypass should return a value of 0."
REFERENCE
"ANSI { fddiATTACHMENT 13 }"
::= { snmpFddiATTACHMENTEntry 5 }

snmpFddiATTACHMENTInsertedStatus OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2), unimplemented(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the attachment is currently inserted in the node."


Case                                                           [Page 41]


RFC 1285                        FDDI MIB                    January 1992


REFERENCE
"ANSI { fddiATTACHMENT 14 }"
::= { snmpFddiATTACHMENTEntry 6 }

snmpFddiATTACHMENTInsertPolicy OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2), unimplemented(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the Insert Policy for this Attachment. Insert: True (1), Don't Insert: False (2), Unimplemented (3)"
REFERENCE
"ANSI { fddiATTACHMENT 15 }"
::= { snmpFddiATTACHMENTEntry 7 }


-- the Chip Set group -- The following object identifiers are allocated for use -- with the snmpFddiMACChipSet and snmpFddiPORTChipSet -- variables.

snmpFddiPHYChipSets -- Chips primarily responsible
-- for implementing the PHY -- function.
OBJECT IDENTIFIER ::= { snmpFddiChipSets 1 }

-- None defined at present -- Chipsets may someday be -- defined here


snmpFddiMACChipSets -- Chips primarily responsible
-- for implementing the -- MAC function.
OBJECT IDENTIFIER ::= { snmpFddiChipSets 2 }

-- None defined at present -- Chipsets may someday be -- defined here

snmpFddiPHYMACChipSets -- Chips which implement both
-- the PHY and MAC functions


Case                                                           [Page 42]


RFC 1285                        FDDI MIB                    January 1992


OBJECT IDENTIFIER ::= { snmpFddiChipSets 3 }

-- None defined at present -- Chipsets may someday be -- defined here

END
6.  Acknowledgements

This document was produced by the IETF FDDI MIB working group:

Steve Adams, Digital Equipment Corporation Hossein Alaee, 3Com Corporation Haggar Alsaleh, Bell Northern Research William Anderson, Mitre Corporation Alan Apt, Addison-Wesley Mary Artibee, Silicon Graphics Karen Auerbach, Epilogue Technologies Doug Bagnall, Apollo/Hewlett Packard Chet Birger, Coral Network Corporation Pablo Brenner, Sparta Howard Brown, Cabletron Jack Brown, US Army Computer Engineering Center Eric Brunner Jeff Case, The University of Tennessee Tammy Chan, Fibercom Asheem Chandna, AT&T Cho Y. Chang, Apollo/Hewlett Packard Chris Chiotasso, Fibronics Paul Ciarfella, Digital Equipment Corporation John Cook, Chipcom Don Coolidge, Silicon Graphics Burt Cyr, Unisys James R. Davin, Massachusetts Institute of Technology Nabil Damouny Nadya El-Afandi, Network Systems Corporation Hunaid Engineer, Cray Research Jeff Fitzgerald, Fibercom Richard Fox, Synoptics Stan Froyd, ACC Debbie Futcher, U.S. Naval Surface Warfare Center Joseph Golio, Cray Research Jeremy Greene, Coral Brian D. Handspicker, Digital Equipment Corporation Peter Hayden, Digital Equipment Corporation Scott Hiles, U.S. Naval Surface Warfare Center Greg Jones, Data General Satish Joshi, SynOptics Communications Jayant Kadambi, AT&T Bell Labs Joanna Karwowska, Data General Frank Kastenholz, Interlan Jim Kinder, Fibercom Christopher Kolb, PSI Cheryl Krupczak, NCR Peter Lin, Vitalink Then Liu John R. LoVerso, Concurrent Computer Corporation Ron Mackey Gary Malkin, Proteon Bruce McClure, Synernetics Keith McCloghrie, Hughes Lan Systems Donna McMaster, SynOptics John O'Hara, Massachusetts Institute of Technology Dave Perkins, SynOptics Communications James E. Reeves, SynOptics Communications Jim Reinstedler, Ungermann-Bass Radhi Renous, Fibronics Anil Rijsinghani, Digital Equipment Corporation Bob Rolla, Synernetics Nelson Ronkin, Synernetics Marshall T. Rose, Performance Systems International, Inc. Milt Roselinsky, CMC Jon Saperia, Digital Equipment Corporation Greg Satz, cisco Systems Steven Senum, Network Systems Corporation Jim Sheridan, IBM Corporation Jeffrey Schiller, MIT Dror Shindelman, Sparta Mark Sleeper, Sparta Craig Smelser, Digital Equipment Corporation Lou Steinberg, IBM Corporation Mary Jane Strohl, Apollo/Hewlett Packard Sally Tarquinio, Mitre Corporation Kaj Tesink, Bellcore Ian Thomas, Chipcom Dean Throop, Data General Bill Townsend, Xylogics Ahmet H. Tuncay, SynOptics Communications Mike Turico, Motorola Chris VandenBerg, ACC Sudhanshu Verma, Hewlett Packard Joe Vermeulen, UNISYS David Waiteman, BBN Bert Williams, Synernetics Mark Wood, AT&T Computer Systems Y. C. Yang Denis Yaro, Sun Microsystems Jeff Young, Cray Research


Case                                                           [Page 43]


RFC 1285                        FDDI MIB                    January 1992





Case                                                           [Page 44]


RFC 1285                        FDDI MIB                    January 1992



The editor gratefully acknowledges the contributions of the editor of the ANSI X3T9.5 SMT document, Mary Jane Strohl of Hewlett Packard/Apollo, whose provision of that document in machine readable form saved much typing and avoided many data entry errors.

The author gratefully acknowledges the labors of Dr. Marshall T. Rose in assisting with converting this document to the new concise MIB format.
8.  References

[1] Rose M., and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based internets", RFC 1155, Performance Systems International, Hughes LAN Systems, May 1990.

[2] McCloghrie K., and M. Rose, "Management Information Base for
Network Management of TCP/IP-based internets", RFC 1156, Hughes LAN Systems, Performance Systems International, May 1990.

[3] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
Network Management Protocol", RFC 1157, SNMP Research, Performance Systems International, Performance Systems International, MIT Laboratory for Computer Science, May 1990.

[4] McCloghrie K., and M. Rose, Editors, "Management Information Base
for Network Management of TCP/IP-based internets", RFC 1213, Performance Systems International, March 1991.

[5] Information processing systems - Open Systems Interconnection -
Specification of Abstract Syntax Notation One (ASN.1), International Organization for Standardization, International Standard 8824, December 1987.

[6] Information processing systems - Open Systems Interconnection -
Specification of Basic Encoding Rules for Abstract Notation One (ASN.1), International Organization for Standardization, International Standard 8825, December 1987.

[7] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
RFC 1212, Performance Systems International, Hughes LAN Systems, March 1991.

[8] American National Standards Institute, "FDDI Station Management
(SMT)", Preliminary Draft Proposed American National Standard, American National Standards Institute, X3T9/90-X3T9.5/84-49 REV 6.2, May 18, 1990.


Case                                                           [Page 45]


RFC 1285                        FDDI MIB                    January 1992



Security Considerations

Security issues are not discussed in this memo.

Author's Address

Jeffrey D. Case SNMP Research, Incorporated 3001 Kimberlin Heights Road Knoxville, Tennessee 37920

Phone: (615) 573-1434

EMail: case@CS.UTK.EDU


































Case [Page 46]


Translate documents to 日本語, svenska, Nederlands, Deutsch, français, русский, italiano, español, Tiếng Việt, polski, português, 中文, українська, català, norsk, فارسی, suomi, Bahasa Indonesia, العربية, čeština, 한국어, Bahasa Melayu, magyar, română, српски and other languages.